Table 15
Troubleshooting the switch (continued)
Issue
An individual component is
not operating as expected.
86
Operating the switch
Possible cause
Component may not have power
or may not be firmly seated.
Pins on the component or the
backplane might be damaged.
The component might have failed.
Recommended action
Ensure component is receiving
power (power LED should be on)
and component is firmly seated.
Remove component from chassis
and inspect pins on card and
inside chassis. Do not reinstall if
pins on either component are
visibly damaged, as this could
damage pins on other component.
Replace parts as required.
Enter the sensorShow command
to determine component status. If
component is a CP card or port
card, enter the slotShow
command to determine status.
Replace component as necessary