Portlogdump - Brocade Communications Systems SN3000B Command Reference Manual

Brocade fabric os command reference - supporting fabric os v7.0.1 (53-1002447-01, march 2012)
Hide thumbs Also See for SN3000B:
Table of Contents

Advertisement

portLogDump

Displays the port log without page breaks.
SYNOPSIS
portlogdump [count[, saved]]
DESCRIPTION
Use this command to display the port log, listing all entries in the log without page breaks. This command
displays the same information as portLogShow, but portLogShow prompts you to press Enter between
each page.
For an explanation of the information displayed by this command, refer to the portLogShow command.
If the port log is disabled while this command is executed, a warning message is displayed. Refer to the
portLogClear command for more information.
NOTES
The execution of this command is subject to Virtual Fabric or Admin Domain restrictions that may be in
place. Refer to Chapter 1, "Using Fabric OS Commands" and Appendix A, "Command Availability" for
details.
OPERANDS
This command has the following operands:
count
saved
EXAMPLES
To display 10lines of the portlog on a Brocade DCX:
SEE ALSO
portLogClear, portLogShow,
Fabric OS Command Reference
53-1001764-01
Specifies the maximum number of lines to be displayed. Only the most recent
count entries are displayed. This operand is optional.
Specify a nonzero value to display the saved port log from the last switch fault.
Refer to upTime for conditions that cause a fault. The operand count is ignored
when displaying the saved log. This operand is optional.
switch:user> portlogdump 10
time
task
-------------------------------------------------
Mon Nov 16 21:52:15 2009
21:52:15.214 FCPH
ed210000,00000000,000073ee,10010082,00008000
21:52:15.214 PORT
02fffffd,00fffffd,0701ffff,13010000
21:52:15.216 FCPH
03fffffd,00fffffd,00000000,00008000,07010000
21:52:15.216 FCPH
ed980000,07010000,00004143,0004001c,00008000
21:52:15.216 FCPH
00fffffd,00fffffd,00000000,00008000,00000000
21:52:15.216 FCPH
ed210000,00000000,000073ee,10010082,00008000
21:52:15.216 PORT
02fffffd,00fffffd,06feffff,13010000
21:52:15.218 FCPH
03fffffd,00fffffd,00000000,00008000,06fe0000
21:52:15.218 FCPH
ed980000,06fe0000,00004143,0004001c,00008000
21:52:15.220 FCPH
ed980000,06fc0000,00004143,0004001c,00008000
upTime
event
port cmd
args
seq
106
7f0
Tx3
106 2032 \
read
106 2032
seq
106
7f0
write
106 2032
seq
106
7f0
Tx3
106 2032 \
read
106 2032
seq
106
7f0 \
seq
106
7f0
2
portLogDump
735

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fabric os v7.0.1

Table of Contents