Perform the following procedure to configure the GVRP port settings:
1. From the main menu on the left side of the page, select Bridge.
The Bridge folder expands.
2. From the Bridge folder, select GVRP.
The GVRP folder expands.
3. From the GVRP folder, select GVRP Time Setting.
The AT-GS950/8 GVRP Time Setting Page is displayed.
See Figure 33.

Figure 33. AT-GS950/8 GVRP Time Setting Page

GARPLeaveTimer must be greater than (GARPJoinTimer x2 + 10).
GARPLeaveAllTimer must be greater than (GARPLeaveTimer + 10).
The acceptable input values are multiples of 10. If you try to enter a
value that is not a multiple of 10, the value will be rounded down.
4. The following fields are listed for each port:
Port - This parameter displays the ports on the switch.
GarpJoinTime - This parameter is the GARP Join Timer. Its range
is 10 - 1073741810 milli-seconds.
GarpLeaveTime - This parameter is the GARP Leave Timer. Its
range is 30 - 2147483630 milli-seconds. This timer must be set in
relation to the GVRP Join Timer according to the following
equation:
GARPLeaveTimer >= (GARPJoinTimer X 2) + 10
GarpLeaveAllTime - This parameter is the GARP Leave Timer.Its
range si 30 - 2147483630 milli-seconds. This timer must be set in
relation to the GVRP Leave Timer according to the following