Chapter 3
NOTE
The message "Configuration of NVRAM and drives mismatch"
indicates that configuration information in the integrated HP
NetRAID controller's NVRAM differs from configuration
information in hard disk drives.
Press any key to start the HP NetRAID Express Tools utility.
On the Tools Management Menu, choose Configure, and then
do one of the following:
To exit HP NetRAID Express Tools, press ESC repeatedly
until the Exit? box appears. Choose YES to exit. Then press
CTRL+ALT+DELETE to restart the NetServer.
2. As soon as you see the message
Press <F2> to enter SETUP
on the display monitor, press the F2 function key.
NOTE
If you wait too long to press the F2 function key, you may not
be able to enter the Setup utility, even though the message
"Press <F2> to enter SETUP" is still displayed. If this happens,
restart the NetServer, and press the F2 function key as soon as
the message appears.
3. If a power-on password has been set, provide it when prompted.
If you do not want RAID on either SCSI A or SCSI B,
choose Clear Configuration.
If you want RAID on SCSI A and you want to use the
configuration stored on the drives, choose
View/Add/Delete Configuration. Then choose View Disk
Configuration. To save that configuration to integrated
HP NetRAID's NVRAM, press ESC and then choose YES
in the Save Configuration? box.
If you want RAID on SCSI A and you want to use the
configuration stored integrated HP NetRAID's NVRAM,
choose View/Add/Delete Configuration. Then choose
View NVRAM Configuration. To save that configuration
to the drives, press ESC and then choose YES in the Save
Configuration? box.
Configure Mass Storage
47