4.1.3.5 Roller Assembly-ADF, CIS, Lever-PC1 and PC2
CIS = Contact Image Sensor
(1) Disassembly procedure
a) First, carry out the disassembly procedures up to the point of the 4.1.3.2 and 4.1.3.3.
b) Dismount the Printer-Unit.
(See Section 4.1.3.19)
c) Remove the Frame assembly-Scanner (L) by removing the four screws 1 and the four connectors.
Screw 1
Disassembly
Frame Assembly-Scanner (L)
4 - 12
Screw 1
(CP4.1 Fig. 17)
OKIOFFICE 44
Service Manual, P/N 59276801
Rev. 2