Displaying The Module Status - Cabletron Systems 3F00-01 User Manual

Fddi dual-attached intelligent module
Table of Contents

Advertisement

Chapter 4: Monitoring and Managing the 3F00-01 and 3F55-01

4.1 DISPLAYING THE MODULE STATUS

To display the status of the 3F00-01 and 3F55-01, at the LCM prompt
type:
ATX >status
Current Number of Learned Addresses: 34
Number of Defined Filters: 2
ModuleType
1
PPE
2
FDDI–IOM
3
CSMA–IOM
4
HSSI–IOM
5
IFDDI–IOM
6
TR–IOM
Displaying the 3F00-01 Port Status
To display the status of a 3F00-01 or 3F55-01 port using LCM, at the
LCM prompt type:
ATX > status <port number>
The port number is determined by counting from the first port on the
top-most module in the ATX, which is the Packet Processing Engine
(PPE).
The status of a 3F00-01 or 3F55-01 port includes:
Type – There are six possible values for the module type, two for the
3F00-01 and four for the 3F55-01. The types are listed below:
-
FDDI DAS
-
FDDI DAS Single Mode
-
Intelligent FDDI DAS
-
Intelligent DAS Single Mode
-
Intelligent DAS Single Mode on MIC A
-
Intelligent DAS Single Mode on MIC B
Bridging – which functions have been enabled for bridging (see the
command).
bridge
Routing – which functions have been enabled for bridging (see the
or
iproute
ipxroute
Page 4-2
DiagStatus
Passed
Passed
Passed
Passed
Passed
Passed
commands).
FDDI Dual-Attached Intelligent Module User's Guide
InUse
TempOk
True
Normal
True
Normal
True
Normal
True
Normal
True
Normal
True
Normal
Ports
1
2
3
4
5
6

Advertisement

Table of Contents
loading

This manual is also suitable for:

3f55-01

Table of Contents