Table 40
Zeroization behavior
Keys
TLS private keys
TLS pre-master secret
TLS session key
TLS authentication key
RADIUS secret

Power-up self tests

The self tests are invoked by powering on the switch in FIPS mode and do not require any operator
intervention. These power-up self tests perform power-on self-tests. If any KATs fail, the switch goes into a
FIPS Error state which reboots the system to start the tests again. If the switch continues to fail the FIPS POST
tests, you will need to boot into single-user mode and perform a recovery procedure to reset the switch. For
more information on this procedure, refer to the Fabric OS Troubleshooting and Diagnostics Guide.

Conditional tests

These tests are for the random number generators and are executed to verify the randomness of the
random number generator. The conditional tests are executed each time prior to using the random number
provided by the random number generator.
The results of all self-tests, for both power-up and conditional, are recorded in the system log or are output
to the local console. This includes logging both passing and failing results.
Refer to the Fabric OS Troubleshooting and Diagnostics Guide for instructions on how to recover if your
system cannot get out of the conditional test mode.

FIPS mode

By default, the switch comes up in non-FIPS mode. You can run the fipsCfg
enable FIPS mode, but you need to confgure the switch first. Self-tests mode must be enabled, before FIPS
mode can be enabled. A set of prerequisites as mentioned in the table below must be satisfied for the
system to enter FIPS mode.
To be FIPS-compliant, the switch must be rebooted. KATs are run on the reboot. If the KATs are successful,
the switch enters FIPS mode. If KATs fail, then the switch reboots until the KATs succeed. If the switch cannot
enter FIPS mode and continues to reboot, you must access the switch in single-user mode to break the
reboot cycle. For more information on how to fix this issue, refer to the Fabric OS Troubleshooting and
Diagnostics Guide.
Only FIPS compliant algorithms will be run at this stage.
Table 41

FIPS mode restrictions

Features
Root account
Telnet/SSH access
SSH algorithms
HTTP/HTTPS access
HTTPS
protocol/algorithms
136 Configuring advanced security features
Zeroization CLI
seccertutil delkey
No CLI required
No CLI required
No CLI required
aaaconfig –-remove
FIPS mode
Disabled
Only SSH
HMAC-SHA1 (mac)
3DES-CBC, AES128-CBC, AES192-CBC,
AES256-CBC (cipher suites)
HTTPS only
TLS/AES128 cipher suite
Description
The command seccertutil delkey is used to
zeroize these keys.
Automatically zeroized on session termination
Automatically zeroized on session termination
Automatically zeroized on session termination
The aaaconfig --remove zeroizes the secret
and deletes a configured server
--
Non-FIPS mode
Enabled
Telnet and SSH
No restrictions
HTTP and HTTPS
TLS/AES128 cipher suite
(SSL will no longer be supported)
enable fips command to