Supported iSCSI initiators
Table 69
Supported iSCSI initiators
iSCSI initiator driver versions
Windows
•
•
•
Linux
•
•
•
•
•
Solaris
•
AIX
•
HP-UX
•
•
NIC/TOE cards
iSCSI HBAs
•
•
Checklist for configuring iSCSI
Configure the iSCSI gateway service after you install the FC4- 1 6IP blade in the 4/256 SAN Director. The
following table provides a high-level overview of the commands and links to the sections that detail the
procedures. See the Fabric OS Command Reference for detailed information on the commands.
Table 70
iSCSI target gateway configuration steps
Step
1
Activate iSCSI for the
FC4- 1 6IP.
2
Configure the IP address
for GbE port(s).
3
Optional) Configure the
IP route for the GbE
port(s).
4
(Easy) Automatically
maps FC targets to iSCSI
targets and names
target with unique IQN.
5
(Advanced) Create
iSCSI virtual target.
6
Add LUNs to the virtual
target.
MS iSCSI initiator 2.02
MS iSCSI initiator 2.03
MS iSCSI initiator 2.04
RH EL 4 default initiator
2.6.10 - 4.0.2 iSCSI initiator (SourceForge,Net initiator)
2.4.20 - 3.6.2 iSCSI initiator (SourceForge,Net initiator)
SUSE 9
SUSE 10
iSCSI is built-in with the 5.1 1 with the latest Solaris Express release
iSCSI is built-in in the 5.3 ML4
1 1i v1 - B.1 1.23.03e
1 1 iv2 - B.1 1.23.03e
Alacritech SES2002XT
Qlogic 4050c
Command
fosConfig - -enable iscsi
portCfg ipif <slot>/ge<port>
create <ipaddress> <netmask>
<mtu_size>
portCfg iproute
<slot>/ge<port> args
iscsiCfg - -easycreate tgt
iscsiCfg - -create tgt –t
<targetname>
iscsiCfg - -add lun -t
<targetname> \
-w <fcwwn> -l <LUN_map>
Procedure
"Enabling the iSCSI gateway
service" on page 258
"Configuring the GbE
interface" on page 259
"Configuring the GbE
interface" on page 259
"Automatic iSCSI VT
creation"
on page 261
"Manual iSCSI VT
creation"
on page 263
Fabric OS 6.1.x administrator guide 255