Using Top Talker Monitors In Port Mode - HP A7533A - Brocade 4Gb SAN Switch Base Administrator's Manual

Hp storageworks fabric os 6.x administrator guide (5697-0015, may 2009)
Hide thumbs Also See for A7533A - Brocade 4Gb SAN Switch Base:
Table of Contents

Advertisement

Using Top Talker monitors in port mode

Use the perfttmon command to add, delete, and display Top Talker monitors. Refer to the Fabric OS
Command Reference for details about the perfttmon command.
To add a Top Talker monitor on an F_Port:
1.
Connect to the switch and log in as admin.
2.
Enter the perfttmon
perfttmon --add [egress | ingress] [slotnumber/]port
where:
slotnumber
port
For example, to monitor the incoming traffic on port 7:
perfttmon --add ingress 7
To monitor the outgoing traffic on slot 2, port 4 on the 4/256 SAN Director or DC Director:
perfttmon --add egress 2/4
To delete a Top Talker monitor on an F_Port:
1.
Connect to the switch and log in as admin.
2.
Enter the perfttmon
perfttmon --delete [slotnumber/]port
where:
slotnumber
port
For example, to delete the monitor on port 7:
perfttmon --delete 7
To delete the monitor on slot 2, port 4 on the 4/256 SAN Director or DC Director:
perfttmon --delete 2/4
To display the top n bandwidth-using flows on an F_Port:
1.
Connect to the switch and log in as admin.
2.
Enter the perfttmon
perfttmon --show [slotnumber/]port [n] [wwn | pid]
where:
slotnumber
port
n
wwn | pid
The output is sorted based on the data rate of each flow. If you do not specify the number of flows to
display, then the command displays the top 8 flows or the total number of flows, whichever is less. The
command can display a maximum of 32 flows.
add command.
--
For director-class switches only (4/256 SAN Director and DC Director), the
slot number.
The port number.
delete command.
--
For director-class switches only (4/256 SAN Director and DC Director), the
slot number.
The port number.
show command.
--
For director-class switches only (4/256 SAN Director and DC Director), the
slot number.
The port number.
The number of top talking flows to display, between 1 and 32.
The format of the output. The default is wwn.
Fabric OS 6.x administrator guide 353