HP A7533A - Brocade 4Gb SAN Switch Base Administrator's Manual page 281

Hp storageworks fabric os 6.x administrator guide (5697-0015, may 2009)
Hide thumbs Also See for A7533A - Brocade 4Gb SAN Switch Base:
Table of Contents

Advertisement

4.
Enter the WWN of the host to be added to the ACL.
5.
At the prompt, enter 1 to display the access list so you can verify that the WWN you entered was
added to the ACL.
6.
After verifying that the WWN was added correctly, enter 0 at the prompt to end the session.
At the "Update the FLASH?" prompt, enter y.
7.
8.
Press Enter to update the nonvolatile memory and end the session.
switch:admin> msconfigure
0
Done
1
Display the access list
2
Add member based on its Port/Node WWN
3
Delete member based on its Port/Node WWN
select : (0..3) [1] 2
Port/Node WWN (in hex): [00:00:00:00:00:00:00:00] 20:00:00:20:37:65:ce:aa
*WWN is successfully added to the MS ACL.
0
Done
1
Display the access list
2
Add member based on its Port/Node WWN
3
Delete member based on its Port/Node WWN
select : (0..3) [2] 1
MS Access List consists of (14): {
20:00:00:20:37:65:ce:aa
20:00:00:20:37:65:ce:bb
20:00:00:20:37:65:ce:ff
20:00:00:20:37:65:ce:11
20:00:00:20:37:65:ce:22
20:00:00:20:37:65:ce:33
20:00:00:20:37:65:ce:44
10:00:00:60:69:04:11:24
10:00:00:60:69:04:11:23
21:00:00:e0:8b:04:70:3b
10:00:00:60:69:04:11:33
20:00:00:20:37:65:ce:55
20:00:00:20:37:65:ce:66
00:00:00:00:00:00:00:00
}
0
Done
1
Display the access list
2
Add member based on its Port/Node WWN
3
Delete member based on its Port/Node WWN
select : (0..3) [1] 0
done ...
Update the FLASH?
*Successfully saved the MS ACL to the flash.
switch:admin>
(yes, y, no, n): [yes] y
Fabric OS 6.x administrator guide 281