To display the top flows on domain 2 in PID format:
perfttmon --show dom 2 pid
switch:admin> perfttmon --show dom 2 pid
========================================
Src_PID
========================================
0xa908ef
0xa05200
0xa905ef
0xa909d5

Limitations of Top Talker monitors

Top Talker monitors cannot detect transient surges in traffic through a given flow.
You cannot install a Top Talker monitor on a mirrored port.
Top Talker can monitor only 10,000 flows at a time.
Top Talker is not supported on VE_Ports, EX_Ports, and VEX_Ports.

Monitoring trunks

For trunked ISLs on Fabric OS 4.x or later switches, monitoring is set only on the master ISL, which
communicates with the associated slave ISLs. Note the following:
For Fabric OS 3.x switches, monitoring can be set on slave ISLs.
End-to-end monitors are not supported for ISLs.
4/8 SAN Switch, 4/16 SAN Switch models support 8 filter-based monitors for trunks.
The SAN Switch 4/32, 4/64 SAN Switch, SAN Switch 4/32B, 400 Multi-protocol Router, 4/256 SAN
Director and DC Director switches support 12 filter-based monitors for trunks.

Displaying monitor counters

Use the perfMonitorShow command to display the monitors on a specified port. For end-to-end
counters, you can display either the cumulative count of the traffic detected by the monitors or a snapshot
of the traffic at specified intervals.
NOTE:
4/8 SAN Switch, 4/16 SAN Switch, SAN Switch 4/32, 4/64 SAN Switch, SAN Switch 4/32B,
400 Multi-protocol Router, 4/256 SAN Director, and DC Director output does not include CRC counts.
The command format is:
perfmonitorshow --class monitor_class [slotnumber/]portnumber [interval]
monitor_class
Dst_PID
MB/sec
0xa05200
6.926
0xa908ef
6.872
0xa05200
6.830
0xa05200
6.772
The monitor class, which can be one of EE (end-to-end), FLT (filter-based), or
ISL (inter-switch link). The
class monitor_class operand is required.
--
Fabric OS 6.x administrator guide 355