Chamberlain CSW200UL Owner's Manual

Chamberlain CSW200UL Owner's Manual

Vehicular swing gate operator
Hide thumbs Also See for CSW200UL:

Advertisement

O W N E R ' S M A N U A L
C S W 2 0 0 U L ™
V E H I C U L A R S W I N G G AT E O P E R AT O R
THE CSW200UL™ IS FOR USE ON VEHICULAR PASSAGE GATES ONLY
AND NOT INTENDED FOR USE ON PEDESTRIAN PASSAGE GATES.
INTENDED FOR PROFESSIONAL INSTALLATION ONLY.
UL325
UL991
compliant
compliant

Advertisement

Table of Contents
loading

Summary of Contents for Chamberlain CSW200UL

  • Page 1 V E H I C U L A R S W I N G G AT E O P E R AT O R THE CSW200UL™ IS FOR USE ON VEHICULAR PASSAGE GATES ONLY AND NOT INTENDED FOR USE ON PEDESTRIAN PASSAGE GATES.
  • Page 3: Table Of Contents

    T A b l E O f c O N T E N T s sPEcIfIcATIONs ANd wARNINgs Overview and Specifications ......2 Mechanical Model Classification .
  • Page 4: Specifications And Warnings

    2 0 0 u l ™ M O d E l s O V E R V I E w s i n g l e M o t o r a n d s t a i n l e s s M o d e l s CSW200UL™ (Single Motor) DC2000™...
  • Page 5: Model Classification

    3 2 5 M O d E l c l A s s I f I c A T I O N s The CSW200UL™ is intended for use in vehicular swing gate applications: Class I – Residential vehicular gate operator A vehicular gate operator (or system) intended for use in a home of one-to four single family dwellings, or a garage or parking area associated therewith.
  • Page 6: Safety Installation Information

    s A f E T Y I N s T A l l A T I O N I N f O R M A T I O N 1. Vehicular gate systems provide convenience and security. Gate systems are comprised of many component parts. The gate operator is only one component.
  • Page 7: Gate Construction Information

    g A T E c O N s T R u c T I O N I N f O R M A T I O N Vehicular gates should be installed in accordance with ASTM F2200: Standard Specification for Automated Vehicular Gate Construction. For a copy, contact ASTM directly at 610-832-9585 or www.astm.org.
  • Page 8: Suggested Entrapment Protection Device Locations

    s u g g E s T E d E N T R A P M E N T P R O T E c T I O N d E V I c E l O c A T I O N s To prevent SERiOuS iNjuRy or DEATh from a moving gate: •...
  • Page 9: Suggested Entrapment Protection Device Locations

    s u g g E s T E d E N T R A P M E N T P R O T E c T I O N d E V I c E l O c A T I O N s To prevent SERiOuS iNjuRy or DEATh from a moving gate: •...
  • Page 10: Safety Precautions

    A f E T Y P R E c A u T I O N s ThE csw200ul™ Is fOR usE ON VEhIculAR PAssAgE gATEs ONlY ANd NOT INTENdEd fOR usE ON PEdEsTRIAN PAssAgE gATEs. To prevent SERiOuS iNjuRy or DEATh from a moving gate: •...
  • Page 11: Installation

    Installation I N s T A l l A T I O N s E T u P s s i n g l e O p e r a t o r Maximum gate length 20 ft. (22 ft. for 1hP) Maximum gate weight is 600 lbs.
  • Page 12: Concrete Pad And Arm Attachment

    c O N c R E T E P A d A N d A R M A T T A c h M E N T To AVOiD damaging operator, DO NOT weld ANy supports to chassis. Chassis MuST be allowed to flex during operation. Concrete Anchors 1/2"...
  • Page 13: Standard Installation Layout

    s T A N d A R d I N s T A l l A T I O N l A Y O u T Sample of standard arm attachment is shown on previous page. Top View of closed gate Bracket Length Bracket Position Gate Hinge...
  • Page 14: Compact Installation Layout

    c O M P A c T I N s T A l l A T I O N l A Y O u T compact Installation ONlY! DO NOT use these measurements for a standard installation. (For standard installation, see previous page.) it is necessary to protect against the entrapment that could occur with this type of installation.
  • Page 15: Uphill Driveway Post Mounting Plate Installation

    u P h I l l d R I V E w A Y I N s T A l l A T I O N ( O P T I O N A l ) Not Possible Gate hits driveway. Possible Special swivel arm and hinges are required.
  • Page 16: Gate Arm Installation

    g A T E A R M I N s T A l l A T I O N Incorrect Installation! Gate Closed Gate Open Correct Installation Once the gate arm measurements are calculated: Arm is on TOP of bracket. Weld the bracket on the gate.
  • Page 17: Control Board Description

    c O N T R O l b O A R d d E s c R I P T I O N 1 HP Board Plug-In Loop Detectors Maglock/Solenoid Relay Module Connection Surge Suppressor UL Alarm Connection Master/Second Connection Photoelectric Sensor Connection W4 Jumper Wire...
  • Page 18: Surge Suppressor Terminal Connections

    Master/Second Connection s u R g E s u P P R E s s O R T E R M I N A l c O N N E c T I O N s Output Power Ground 24Vdc 120Vac Power Removable...
  • Page 19: Earth Ground Rod Installation

    Wiring To reduce the risk of SEVERE iNjuRy or DEATh: • DO NOT install ANy wiring or attempt to run the operator without consulting the wiring diagram. We recommend that • ANy maintenance to the operator or in the area near the you install an optional reversing edge BEFORE proceeding operator MuST not be performed until disconnecting the with the control station installation.
  • Page 20: 110Vac Power Connection

    1 1 0 V a c P O w E R c O N N E c T I O N On-Off switch for operator Green Ground Black 110Vac White Neutral use a 20 amp dedicated circuit for each operator. input power 120Vac, 60 hz.
  • Page 21: Linking Master/Second Operators

    l I N k I N g M A s T E R / s E c O N d O P E R A T O R s Use a 20 amp dedicated power circuit for each operator. Never run high voltage and low voltage wires in same conduit. Run low voltage 16-18 gauge wire in UL approved conduit to link operators together.
  • Page 22: Solenoid/Maglock Connections

    s O l E N O I d / M A g l O c k R E l A Y c O N N E c T I O N Connection of a solenoid or magnetic lock can be made using the j7 board connector and “Optional” Relay Adapter Module. Relay Contact Rating 2 Amp - 125 AC/DC 2 Amp switching load...
  • Page 23: Dc2000 Back-Up Connections

    f A c T O R Y I N s T A l l E d d c 2 0 0 0 ™ c O N N E c T I O N d c 2 0 0 0 ™ s t a r t u p Plug in the 12 pin plug into the DC2000™...
  • Page 24 d c 2 0 0 0 ™ d E V I c E w I R I N g M a n u a l l y O p e r a t e d d c 2 0 0 0 ™ d e v i c e s Manual external devices should be dry-contact which do not consume any current like push buttons or a key switch.
  • Page 25: Plug-In Loop Detector Wiring

    P l u g - I N l O O P d E T E c T O R w I R I N g Plug-In Loop Detectors (Sold individually) The wire MuST be twisted together To AVOiD damaging control board, Series Connected 6 twists per foot disconnect all power to operator before...
  • Page 26: 110Vac External Loop Detector Wiring

    1 1 0 V a c E X T E R N A L L O O P D E T E C T O R W I R I N G (Sold Individually) 110Vac “Center” Loop Detector: Allows gate to stay open when vehicles are obstructing path.
  • Page 27: Entrapment Protection Devices (Edge Sensors)

    E N T R A P M E N T P R O T E c T I O N d E V I c E s contact sensors (Edge sensor) 3 Edge Contact Sensor To prevent SERiOuS iNjuRy or DEATh from a moving gate: •...
  • Page 28: Entrapment Protection Devices (Non-Contact Sensors)

    E N T R A P M E N T P R O T E c T I O N d E V I c E s Non-contact sensors (12Vdc Photoelectric sensors) To prevent SERiOuS iNjuRy or DEATh from a moving gate: •...
  • Page 29: Set Gate Opening Direction

    Adjustments To reduce the risk of SERiOuS iNjuRy or DEATh: Disconnect power BEFORE performing ANy adjustments. s E T g A T E O P E N I N g d I R E c T I O N Open to the RIGHT Open to the LEFT...
  • Page 30: Limit Switch Adjustments

    l I M I T s w I T c h A d j u s T M E N T Release the red safety handle and move the gate to the open position. Loosen the screw on one of the limit cams and turn the cam until the half moon shape hits the limit switch and you hear the switch click.
  • Page 31 3 1 5 M h Z 2 4 V d c R A d I O R E c E I V E R P R O g R A M M I N g setting security Mode (high) or (Normal): The receiver is factory set at HIGH security mode.
  • Page 32: Radio Receiver Programming

    3 1 5 M h 2 4 V d c R A d I O R E c E I V E R P R O g R A M M I N g NOTICE: To comply with FCC and or industry Canada (iC) rules, adjustment or modifications of this receiver IMPORTANT: Hand-held remote NOT included.
  • Page 33: Setting The Timer (On, Off)

    s E T T I N g T h E T I M E R s i n g l e O p e r a t o r To use the automatic close for the gate system the timer switch should be put in the “ON”...
  • Page 34: Adjusting Reversing Sensor(S)

    A d j u s T I N g R E V E R s I N g s E N s O R ( s ) Adjust the “Reverse Sensor” on the OmniControl™ board. Alarm Sensor does not need to be adjusted except where noted below. The level of reverse sensitivity depends on the weight of the gate and the condition of installation.
  • Page 35: Omnicontrolâ„¢ Board Connections

    O M N I c O N T R O l ™ b O A R d c O N N E c T I O N s Purchased separately from Chamberlain Elite ® NOTE: Refer to the OmniControl™ board manual for more specific information.
  • Page 36: Maintenance And Operation

    Maintenance and Operation IMPORTANT SAfETY INSTRUCTIONS To reduce the risk of SEVERE INJURY or DEATH: 1. READ AND FOLLOW ALL iNSTRuCTiONS. 5. use the emergency release ONLy when the gate is not moving. 2. NEVER let children operate or play with gate controls. Keep the remote control away from children.
  • Page 37: Built-In Reset Switch

    b u I l T - I N R E s E T s w I T c h When the gate operator’s audio alarm (see below) has been tripped, the reset switch must be pushed for the operator to function again. The reset switch will shut off an activated audio alarm and reset the operator to function again.
  • Page 38: Emergency Manual Release

    E M E R g E N c Y M A N u A l R E l E A s E NOTE: Use the dedicated breaker switch to disconnect power to the operator. Unscrew star knob. Lift off cover. Loosen red handle as shown.
  • Page 39: Wiring Diagrams And Spec Tables

    w i r i n g d i a g r a m • C S w 2 0 0 u l ™ a n d C S w 2 0 0 u l d m ™ NOTE: See table on next page.
  • Page 40 w i r i n g t a b l e • C S w 2 0 0 u l ™ a n d C S w 2 0 0 u l d m ™ OmniControl™ Board J Pin # Signal Type Direction Level (+/- 10%)
  • Page 41 w i r i n g d i a g r a m • C S w 2 0 0 u l 1 H P ™ NOTE: See table on next page.
  • Page 42 w i r i n g t a b l e • C S w 2 0 0 u l 1 H P ™ OmniControl™ Board J Pin # Signal Type Direction Level (+/- 10%) Input Connection Safety Loop 5 or 0Vdc External Loop Detector input Power Neutral Wires,...
  • Page 43 w i r i n g d i a g r a m • d C 2 0 0 0 ™ f o r S i n g l e a n d d m NOTE: This diagram only shows the DC2000™...
  • Page 44 w i r i n g t a b l e • d C 2 0 0 0 ™ J Pin # Signal Type Direction Level (+/- 10%) Input Connection Open N.O. 5 or 0Vdc Closed N.O. 5 or 0Vdc •...
  • Page 45: Troubleshooting

    Troubleshooting The gate will Not Operate with Remote: The radio receiver LED The gate will Not Operate with Remote: The radio receiver LED on the control board remains “ON” when using the remote on the control board remains “OFF” when using the remote control.
  • Page 46 T R O u b l E s h O O T I N g ( c O N T I N u E d ) Condition Probable Causes Solution 1. Short circuit at terminals 11 and 13. 1. Remove the short circuit condition at the Overload LED ON 2.
  • Page 47: Repair Parts

    Repair Parts Q269 K45-50676 Q084 Q118 Q268 Q062 Q244 Q061 Q059 Q057 Q216 Q247 Q018 Q044 Q210 312hM Q027 Q523 Q212 Q025 Q029* Q166 Q018 Q520 Q521 Q407 Q175 Q183 Q025 Q046 Q408 Q400E-1 Q045 Q220 Q401 Q402 Q006 G6518CSW Q409 Q410 Q404...
  • Page 48 Q183 - Sprocket (B50-16) Q212 - Gear Reducer 40-30:1 Q216 - Output Shaft for 70 Reducer Electronic Box Assembly - Q402 Q220 - CSW200uL™ Chassis for 70 Reducer - Electronic Metal Box Q244 - Cover - hD Polyethylene - Surge Suppressor...
  • Page 49: Accessories

    Accessories Standard Arm Part # Q104 Magnetic Lock (Outdoor) Remote Controls Omni Relay Adapter Part # MG1300 Swivel Arm Part # Q400MAu Part # Q103 For more information about accessories: Heater Kit www.chamberlain.com Part # G6518CSW Stop Button OmniControl™ Board Part # AEXiTP Part #...
  • Page 50 System Diagram...
  • Page 51 System Diagram...
  • Page 52 System Diagram...
  • Page 53: Installation Checklist

    Installation Checklist 1. Owner and installer must read all warnings and safety precautions. 2. Make sure concrete mounting pad is big enough and deep enough for operator. 3. Operator must be securely fastened to concrete pad or mounting plate. 4. Operator arm must be level and welded properly to gate. 5.
  • Page 54: Warranty Policy

    7 year residential/ 5 year commercial from the date of purchase [and that the CSW200uL™ is free from defect in materials and/or workmanship for a period of 7 year residential/ 5 year commercial from the date of purchase].
  • Page 56 CSW200UL™ UL325 UL991 compliant compliant 845 Larch Avenue Elmhurst, Illinois 60126-1196 © 2009, The Chamberlain Group, Inc. – All Rights Reserved 01-50396F...

Table of Contents