Earth Ground Rod Installation - Chamberlain CSW200UL Owner's Manual

Vehicular swing gate operator
Hide thumbs Also See for CSW200UL:
Table of Contents

Advertisement

To reduce the risk of SEVERE iNjuRy or DEATh:
• ANy maintenance to the operator or in the area near the
operator MuST not be performed until disconnecting the
electrical power and locking-out the power. upon completion
of maintenance the area MuST be cleared and secured, at
that time the unit may be returned to service.
• Disconnect power at the fuse box BEFORE proceeding.
Operator MuST be properly grounded and connected in
accordance with local electrical codes.
NOTE: The operator should be on a separate fused line of
adequate capacity.
• ALL electrical connections MuST be made by a qualified
individual.
110Vac Power Wire
1/2 HP and Dual Motor
1 HP
E A R T h g R O u N d R O d I N s T A l l A T I O N
3 Feet
Single
piece of 12
gauge wire.
Check
local
codes for
proper
depth.
16 Gauge
14 Gauge
up to 150 FT
250 FT
up to 75 FT
125 FT
Proper grounding gives an electrical charge, such as from an electrical static
discharge or a near lightning strike, a path from which to dissipate its energy
safely into the earth.
Without this path, the intense energy generated by lightning could be directed
towards the gate operator. Although nothing can absorb the tremendous power of a direct lightning
strike, proper grounding can protect the gate operator in most cases.
The earth ground rod must be located within 3 feet from the gate operator. use the proper type earth
ground rod for your local area. The ground wire must be a single, whole piece of wire. Never splice
two wires for the ground wire. if you should cut the ground wire too short, break it, or destroy its
integrity, replace it with a single wire length.
Wiring
• DO NOT install ANy wiring or attempt to run the operator
without consulting the wiring diagram. We recommend that
you install an optional reversing edge BEFORE proceeding
with the control station installation.
• ALL power wiring should be on a dedicated circuit and well
protected. The location of the power disconnect should be
visible and clearly labeled.
• ALL power and control wiring MuST be run in separate
conduit.
• BEFORE installing power wiring or control stations be sure to
follow ALL specifications and warnings described below.
Failure to do so may result in SEVERE iNjuRy to persons
and/or damage to operator.
• DO NOT disconnect the built-in audio alarm or reset switch.
12 Gauge
10 Gauge
400 FT
200 FT
To prevent SERiOuS iNjuRy or DEATh from a moving gate:
DO NOT disconnect the built-in audio alarm or reset switch.
To AVOiD damaging gas, power, or other underground utility
lines, contact underground utility locating companies BEFORE
digging more than 18 inches (46 cm) deep.
17
8 Gauge
650 FT
1000 FT
325 FT
500 FT
4 Gauge
2200 FT
1100 FT