w i r i n g t a b l e • C S w 2 0 0 u l ™ a n d C S w 2 0 0 u l d m ™
J #
J Pin #
J1
1
J1
2
J1
3
J1
4
J1
5
J1
6
J1
7
J1
8
J1
9
J1
10
J2
10 Pins
J3
1
J3
2
J3
3
Normally Closed (No Wire)
J3
4
J3
5
Limit Switch Brown Com
J3
6
J3
7
J3
8
J3
9
Limit Switch yellow Com
J3
10
Limit Switch Orange N.O.
J5
1
J5
2
J5
3
J5
4
J5
5
J5
6
J5
7
J6
1
J6
2
J6
3
J6
4
J7
1
J7
2
J7
3
J8
1
Plug-in Exit Loop Wire
J8
2
Plug-in Exit Loop Wire
J8
3
Plug-in Safety Loop Wire
J8
4
Plug-in Safety Loop Wire
J8
5
Plug-in Center Loop Wire
J8
6
Plug-in Center Loop Wire
J9
16 Pins
J10
1
J10
2
J10
3
J11
10 Pins
J12
10 Pins
J13
10 Pins
J1
1
J1
2
J1
3
J2
Fire Dept. Key Switch (7)
1
Fire Dept. Key Switch (8)
J2
2
J2
Strike Open Push Button (9)
3
Strike Open Push Button (10)
J2
4
J2
5
J2
6
J2
7
Center External Loop Detector (1)
J3
1
Center External Loop Detector (2)
J3
2
Safety External Loop Detector (3)
J3
3
Safety External Loop Detector (4)
J3
4
Exit External Loop Detector (5)
J3
5
Exit External Loop Detector (6)
J3
6
OmniControl™ Board
Signal Type
Safety Loop
input Power Neutral
Center Loop
input Power 120Vac
Strike Open
Exit Loop
Radio Receiver –
Radio Receiver
Fire Dept Key Switch
Radio Receiver +
OmniControl™ Board
Limit Switch Red N.O.
Motor White
Motor Black
Motor Green
Purple Com
Blue N.O.
–
Reset Switch Red
–
Reset Switch Black
–
–
–
uL Alarm Red
uL Alarm Black
Photoelectric Sensor
Photoelectric Sensor
Relay Adapter Red
Relay Adapter White
Relay Adapter Black
1 hP Board
G M/S Link
B M/S Link
A M/S Link
Center Loop Detector
Safety Loop Detector
Exit Loop Detector
OmniControl™ Surge Suppressor
G M/S Link (G)
B M/S Link (B)
A M/S Link (A)
Radio Receiver – (11)
Radio Receiver (12)
Radio Receiver + (13)
Direction
Level (+/- 10%)
in
5 or 0Vdc
in
0V
in
5 or 0Vdc
in
120Vac
in
5 or 0Vdc
in
5 or 0Vdc
in
0V
in
0V
in
Dry
Out
24Vdc
Out
24Vdc
Out
0Vdc
Out
0V
in
5 or 0Vdc
Out
120Vac
in
0V
Out
120Vac
in
0V
in
5 or 0Vdc
in
0V
in
5 or 0Vdc
in
–
in
Dry
in
–
in
Dry
in
–
in
–
in
–
Out
24Vdc
Out
0Vdc
in
5 or 0Vdc
in
0V
in
5 or 0Vdc
in
0Vdc
in
0Vdc
in
2 to 10Vdc
in
2 to 10Vdc
in
2 to 10Vdc
in
2 to 10Vdc
in
2 to 10Vdc
in
2 to 10Vdc
–
–
in/Out
0Vdc
in/Out
5 or 0Vdc
in/Out
5 or 0Vdc
in
5 or 0Vdc
in
5 or 0Vdc
in
5 or 0Vdc
in/Out
0V
in/Out
5 or 0Vdc
in/Out
5 or 0Vdc
in
Dry
in
Dry
in
5 or 0Vdc
in
0V
in
0V
in
5 or 0Vdc
Out
24Vdc
in
2 to 10Vdc
in
2 to 10Vdc
in
2 to 10Vdc
in
2 to 10Vdc
in
2 to 10Vdc
in
2 to 10Vdc
38
Input Connection
External Loop Detector
Wires,
120Vac Power,
Radio Receiver,
Strike Open,
Key Switch
harness
OmniControl™ Board input
Motor(s),
Limit Switches,
Maglock/Solenoid
harness
Reset Switch
input
uL Alarm and
Photoelectric Sensors
Relay Adapter
Module input
Plug-in Loop
Detector Wires
Not used
Master/Second Link
Plug-in Loop
Detector inputs
Master/Second Link
input
Radio Receiver,
Strike Open Push Button,
Fire Dept Key Switch
inputs
External Loop
Detector Center,
Safety, Exit Wires
input
NOTE: See diagram on previous page.