U L 3 2 5 M O D E L C L A S S I F I C AT I O N S The CSW200UL™ is intended for use in vehicular swing gate applications: Class I – Residential vehicular gate operator A vehicular gate operator (or system) intended for use in a home of one-to four single family dwellings, or a garage or parking area associated therewith.
S A F E T Y I N S TA L L AT I O N I N F O R M AT I O N 1. Vehicular gate systems provide convenience and security. Gate systems are comprised of many component parts. The gate operator is only one component.
S U G G E S T E D E N T R A P M E N T P R O T E C T I O N D E V I C E L O C AT I O N S WARNING To prevent SERIOUS INJURY or DEATH from a moving gate: •...
Page 7
S U G G E S T E D E N T R A P M E N T P R O T E C T I O N D E V I C E L O C AT I O N S WARNING To prevent SERIOUS INJURY or DEATH from a moving gate: •...
S A F E T Y P R E C A U T I O N S THE CSW200UL™ IS FOR USE ON VEHICULAR PASSAGE GATES ONLY AND NOT INTENDED FOR USE ON PEDESTRIAN PASSAGE GATES. WARNING To prevent SERIOUS INJURY or DEATH from a moving gate: •...
C O N C R E T E PA D A N D A R M AT TA C H M E N T CAUTION To AVOID damaging operator, DO NOT weld ANY supports to chassis. Chassis MUST be allowed to flex during operation. Concrete Anchors 1/2"...
S TA N D A R D I N S TA L L AT I O N L AY O U T Sample installation is shown on previous page. Top View of Closed Gate Bracket Length Bracket Position Gate Hinge Mount bracket at least a quarter of the gate length from the gate hinge.
C O M PA C T I N S TA L L AT I O N L AY O U T Compact Installation ONLY! DO NOT use these measurements for a standard installation. (For standard installation, see previous page) It is necessary to protect against the entrapment that could occur with this type of installation.
U P H I L L D R I V E W AY I N S TA L L AT I O N ( O P T I O N A L ) Not Possible Gate hits driveway. Possible Special swivel arm and hinges are required. Swivel Arm Part # Q103...
G AT E A R M I N S TA L L AT I O N Incorrect Installation! Gate Closed Gate Open Correct Installation Once the gate arm measurements are calculated: Arm is on TOP of bracket. Weld the bracket on the gate. Weld the longer arm..
O m n i C o n t r o l ™ B O A R D D E S C R I P T I O N Board Wiring Diagrams on pages 36 through 41. 1 HP Board Plug-In Loop Detectors (See page 22) CENTER SAFETY EXIT...
Wiring WARNING • DO NOT install any wiring or attempt to run the operator To reduce the risk of SEVERE INJURY or DEATH: without consulting the wiring diagram. We recommend that • ANY maintenance to the operator or in the area near the you Install an optional reversing edge BEFORE proceeding operator MUST not be performed until disconnecting the with the control station installation.
1 1 0 V a c P O W E R C O N N E C T I O N On-Off switch for operator. Green Ground Black 110 Vac White Neutral Use a 20 amp dedicated circuit for each operator. Input power 120 Vac, 60 Hz.
L I N K I N G M A S T E R / S E C O N D O P E R AT O R S Use a 20 amp dedicated power circuit for each operator. Never run high voltage and low voltage wires in same conduit. Run low voltage 16-18 gauge wire in UL approved conduit to link operators together.
S O L E N O I D / M A G L O C K J 3 C O N N E C T I O N Connect a solenoid or magnetic lock using the J3 plug and two wires (Blue, Purple) supplied with the unit. Solenoid Lock Solenoid Lock J3 J3...
F A C T O R Y I N S TA L L E D D C 2 0 0 0 ™ C O N N E C T I O N D C 2 0 0 0 ™ S t a r t u p Plug in the 12 pin plug into the DC2000™...
Page 22
D C 2 0 0 0 ™ D E V I C E W I R I N G M a n u a l l y O p e r a t e d D C 2 0 0 0 ™ D e v i c e s Manual external devices should be dry-contact which do not consume any current like push buttons or a key switch.
P L U G - I N L O O P D E T E C T O R W I R I N G Plug-In Loop Detectors Part # AELD (Sold Individually) CENTER SAFETY EXIT POWER ON POWER ON DETECT DETECT LOOP FAIL...
E N T R A P M E N T P R O T E C T I O N D E V I C E S Contact Sensors (Edge Sensor) WARNING 3 Edge Contact Sensor To prevent SERIOUS INJURY or DEATH from a moving gate: •...
E N T R A P M E N T P R O T E C T I O N D E V I C E S Non-Contact Sensors (24 VDC Photo Electric Sensors) WARNING To prevent SERIOUS INJURY or DEATH from a moving gate: •...
Adjustments CAUTION To reduce the risk of SERIOUS INJURY or DEATH: Disconnect power BEFORE performing ANY adjustments. S E T G AT E O P E N I N G D I R E C T I O N CENTER SAFETY EXIT OPEN RIGHT...
L I M I T S W I T C H A D J U S T M E N T Release the red safety handle and move the gate to the open position. Loosen the screw on one of the limit cams and turn the cam until the half moon shape hits the limit switch and you hear the switch click.
3 1 5 M H Z 2 4 V D C R A D I O R E C E I V E R P R O G R A M M I N G Setting Security Mode (High) or (Normal): The receiver is factory set at HIGH security mode.
Page 30
3 1 5 M H Z 2 4 V D C R A D I O R E C E I V E R P R O G R A M M I N G IMPORTANT: Hand Held Remote NOT Included. NOTICE: To comply with FCC and or Industry Canada (IC) rules, adjustment or modifications of this receiver and/or transmitter are prohibited, except for changing the code setting or replacing the battery.
A D J U S T I N G R E V E R S I N G S E N S O R ( S ) Adjust the “Reverse Sensor” on the OmniControl™ board. Alarm Sensor does not need to be adjusted except where noted below. The level of reverse sensitivity depends on the weight of the gate and the condition of installation.
O M N I O P T I O N B O A R D C O N N E C T I O N S Purchased separately from Chamberlain Elite. Part# OOMNIEXB NOTE: Refer to the Omni Option Board manual for more specific information.
9. ALL maintenance MUST be performed by a Failure to adjust and retest the gate operator properly Chamberlain Elite professional. can increase the risk of INJURY or DEATH. SAVE THESE INSTRUCTIONS.
B U I LT- I N R E S E T S W I T C H When the gate operator’s audio alarm (See below) has been tripped, the reset switch must be pushed for the operator to function again. The reset switch will shut off an activated audio alarm and reset the operator to function again.
E M E R G E N C Y M A N U A L R E L E A S E NOTE: Use the dedicated breaker switch to disconnect power to the operator. Unscrew Star Knob. Lift Off Cover. Loosen Red Handle as Shown.
W I R I N G D I A G R A M • C S W 2 0 0 U L ™ A N D C S W 2 0 0 U L D M ™ Electronic Power Strip White White Neutral...
Page 38
W I R I N G TA B L E • C S W 2 0 0 U L ™ A N D C S W 2 0 0 U L D M ™ OmniControl™ Board J Pin # Signal Type Direction Level (+/- 10%) Input Connection...
Page 39
W I R I N G D I A G R A M • C S W 2 0 0 U L 1 H P ™ Electronic Power Strip White White Neutral Wires Black Black Wires 110 Vac Chassis Ground 1 HP Board OmniControl™...
Page 40
W I R I N G TA B L E • C S W 2 0 0 U L 1 H P ™ OmniControl™ Board J Pin # Signal Type Direction Level (+/- 10%) Input Connection Safety Loop 5 or 0 VDC External Loop Detector Input Power Neutral Wires,...
Page 41
W I R I N G D I A G R A M • D C 2 0 0 0 ™ F O R S I N G L E A N D D M NOTE: This diagram only shows the DC2000™...
Page 42
W I R I N G TA B L E • D C 2 0 0 0 ™ J Pin # Signal Type Direction Level (+/- 10%) Input Connection 5 or0 VDC Open N.O. Closed N.O. 5 or 0 VDC •...
Troubleshooting The Gate Will Not Operate with Remote: The radio receiver LED The Gate Will Not Operate with Remote: The radio receiver LED on the control board remains “ON” when using the remote on the control board remains “OFF” when using the remote control.
Page 44
T R O U B L E S H O O T I N G ( C O N T I N U E D ) Condition Probable Causes Solution 1. Short circuit at terminals 11 and 13. 1. Remove the short circuit condition at the Overload LED ON 2.
Page 46
• PART NUMBER • PART NAME • MODEL NUMBER Address orders to: THE CHAMBERLAIN GROUP, INC. Technical Support Group 6020 S. Country Club Road Tucson, Arizona 85706 R E PA I R PA R T N A M E S A N D N U M B E R S...
Swivel Arm Part # Q400MAU Part # CPSN4 Page 12 Part # Q103 For more information about accessories: Heater Kit www.chamberlain.com Part # G6518CSW Magnetic Lock (Outdoor) Page 19 and 32 Part # MG1300 Omni Option Board Page 32 Part #...
Installation Checklist 1. Owner and Installer must read all warnings and safety precautions. (Pages 3-7) 2. Make sure concrete mounting pad is big enough and deep enough for operator. (Page 9) 3. Operator must be securely fastened to concrete pad or mounting plate. (Page 9) 4.
7 YEAR RESIDENTIAL/ 5 YEAR COMMERCIAL CSW200UL™ LIMITED WARRANTY The Chamberlain Group, Inc. (“Seller”) warrants to the first retail purchaser of this product, for the structure in which this product is originally installed, that it is free from defect in materials and/or workmanship for a period of 7 year residential/ 5 year commercial from the date of purchase [and that the CSW200UL™...