3 1 5 M h Z 2 4 V d c R A d I O R E c E I V E R P R O g R A M M I N g
setting security Mode (high) or (Normal):
The receiver is factory set at HIGH security mode. To verify, refer to the label next to jumper P4. (See illustration below.)
The Receiver can be used with up to 15 rolling code remotes or passwords in HIGH security mode. Alternately, it can be used with up
to 31 of any type remote in NORMAL security mode, including any combination of rolling code, billion code, or dip switch remotes.
When changing from NORMAL to HIGH security mode, all previous remote control codes must be erased. See next page to erase and
reprogram remote controls that are being used.
To AVOiD damaging receiver, disconnect receiver's power
BEFORE changing jumpers.
Changing output duration from Momentary to Constant.
setting Output duration (M) or (c):
The receiver is factory set at (M) Momentary. To verify, refer to the label next to jumper P2. (See illustration above.)
For commercial applications, the receiver can be set to either (C) constant or (M) momentary closure.
With the jumper in the (M) momentary position, the contacts will close for 1/4 second regardless of the length of remote control
transmission.
With the jumper in (C) constant position, the contacts will stay closed as long as the remote control continues transmitting. Push and
HOLD remote button to open or close gate.
P4
P2
To reduce the risk of SERiOuS iNjuRy or DEATh from a
moving gate:
• ALWAyS keep remote controls out of reach of children.
NEVER permit children to operate, or play with remote control.
• Activate gate ONLy when it can be seen clearly, is properly
adjusted, and there are no obstructions in gate's path.
• ALWAyS keep gate in sight until completely closed. NEVER
permit anyone to cross path of a moving gate.
Changing security from high to Normal.
To reduce the risk of SERiOuS iNjuRy or DEATh, the use of
CONSTANT OPERATiON on residential operators is
PROhiBiTED.
29