To reduce the risk of INJURY or DEATH:
• DISCONNECT power BEFORE installing or servicing operator.
• Replace ONLY with fuse of same type and rating.
• To be compliant with UL325 and industry safety guidelines, qualified monitored
external entrapment protection devices such as photoelectric sensors or edge
sensors are required to be installed with this operator at each entrapment zone.
Use ONLY LiftMaster approved entrapment protection devices (refer to the
accessory page of manual).
• See manual prior to servicing regarding maintenance and required safety testing.
Diagnostic Codes
TO VIEW THE CODES:
Press and hold
...then press and
...then press and hold OPEN
STOP...
hold CLOSE...
until "Er" shows.
The operator will show the code sequence number followed by the code number:
A SECOND LATER....
CODE SEQUENCE NUMBER
CODE NUMBER
The first number shown is the most recent
The second number shown after the code
code (example: "01"). The display will show
sequence number is the code itself
the sequence of codes that occurred starting
(31-99, example" "31").
with "01" and going up to code "20".
CODE COLOR KEY:
LiftMaster System
External Entrapment Protection
Installed System
Inherent Entrapment Protection
Informational
MEANING
SOLUTION
Main control board has
Disconnect all power, wait 15 seconds, then reconnect power
31
experienced an internal
(reboot). If issue continues, replace main control board.
failure.
Max-Run-Time Exceeded
Attempt to run and review for duration and obstructions.
35
Error
Max-Run-Time can be re-measured by saving one or both of
the limits again.
Product ID Error
Was the control board just replaced? If so, erase limits, enter
limit setup mode and set limits. If not, disconnect all power,
36
wait 15 seconds, then reconnect power before changing
product ID harness.
Product ID Failure
Unplug product ID harness then plug back in. Disconnect all
37
power, wait 15 seconds, then reconnect power before
replacing product ID harness.
43
Failure or missing EXIT loop
Check loop wiring throughout connection. May be a short in
the loop, or an open connection in the loop (LiftMaster Plug-
Failure or missing SHADOW
44
in Loop Detector only).
loop
Failure or missing
45
INTERRUPT loop
46
Wireless edge battery low
Replace batteries in wireless edge.
Power board fault
Relay fault detected in the power board. Replace the power
47
board.
Run-Distance Error
Limits are less than 4 feet apart or longer than what was
50
learned. Check limit positions and proper switch function.
Run-distance can be re-learned by setting the handing again.
Brownout occurred
AC/DC board supply dipped below allowable level. Review
53
power supply and wiring. If rebooting, ensure enough time
for discharge of power to force a fresh boot.
Wireless Second Operator
Check the second operator for power. If OFF, restore power
54
Communication Error
and try to run the system. If powered, deactivate the wireless
feature and then re-learn the second operator.
55
System AC Overvoltage
Call utility.
56
System AC Undervoltage
Check wiring and wire gauge to operator.
Limit Error - Stuck Switch
Check switch for proper operation. Check harness for shorts.
57
Replace if defective.
58
Limit Error - Wrong Switch
Check motor wiring.
Missing Power Board
Check harness for shorts. Check for presence of power
59
board.
Minimum number of
Review monitored entrapment protection device connections.
monitored entrapment
Slide gate operators require a minimum of two external
protection devices not
safety devices; one in the close and one in the open
60
installed.
direction. Swing gate operators require one external safety
device in either the open or close direction.
CLOSE EYE/INTERRUPT held
Check wired input on main board; check for alignment or
61
more than 3 minutes
obstruction.
CLOSE EDGE held more than
62
3 minutes
OPEN EYE/EDGE held more
63
than 3 minutes
CLOSE EYE/INTERRUPT held
Check wired input on expansion board; check for alignment
64
more than 3 minutes
or obstruction.
CLOSE EYE/EDGE held more
65
than 3 minutes
OPEN EYE/EDGE held more
66
than 3 minutes
Wireless edge triggered more
Check wired input for wiring issue or obstruction.
67
than 3 minutes
Wireless edge loss of
Check wireless edge inputs.
68
monitoring
Wireless edge triggered
IF an obstruction occurred, no action required. If an
69
obstruction did NOT occur, check inputs and wiring.
CLOSE EYE/INTERRUPT
IF an obstruction occurred, no action required. If an
triggered, causing reversal,
obstruction did NOT occur, check alignment, inputs, and
70
preventing close, or resetting
wiring on main board.
TTC
CLOSE EDGE triggered,
71
causing reversal, preventing
close, or canceling TTC
OPEN EYE/EDGE triggered,
72
causing reversal or
preventing opening
CLOSE EYE/INTERRUPT
IF an obstruction occurred, no action required. If an
triggered, causing reversal,
obstruction did NOT occur, check alignment, inputs, and
73
preventing close, or resetting
wiring on expansion board.
TTC
CLOSE EYE/EDGE triggered,
causing reversal and
74
preventing close or canceling
TTC
OPEN EYE/EDGE triggered,
75
causing reversal or
preventing opening
Close input (EYE/EDGE)
Check inputs and communication method between operators,
80
communication fault from
either wired bus or radio. Ensure operator is powered. May
other operator
have to erase the wireless communication and reprogram the
two operators.
Open input (EYE/EDGE)
81
communication fault from
other operator
Close input (EYE/EDGE)
Check the connections between the main board and the
82
communication fault
expansion board.
(expansion board)
Open input (EYE/EDGE)
83
communication fault
(expansion board)
Non-monitored device
Non-monitored contact closure devices are not supported.
84
detected on the wireless
Make sure connected devices are monitored. Check edges
safety system
for proper orientation and resistive end cap connection.
Force Reversal
Look for obstruction, if no obstruction, check that the
mechanical assembly is engaged and free to move. Refer to
91
manual for Limit and Force Adjustment, and Obstruction
Test.
RPM / STALL Reversal
Check for obstruction. If no obstruction, check the operator
93
cable wiring and that the operator arm is engaged and free to
move. Replace RPM assembly.
AC motor no start condition
Motor failed to start. Check for an obstructed gate or binding
95
mechanism. Check start capacitor connections and condition.
Current Sensor Fault
A fault was detected on the current sensor. Make sure the
current sensor is connected to the main control board. Check
96
the current sensor harness for an open or short. The operator
will need a power cycle to resume operation after correcting
the fault. If the fault continues, replace the power board.
99
Normal Operation
No action required
CONTROL BOARD
ANTENNA
4 3 2 1
2 1
10
9
8 7 6 5 4 3 2 1
4 3 2 1
2 1
Yellow
Yellow
RESET BUTTON
PRODUCT ID
SL3000UL - Yellow
CSW200UL -Purple
Red
Black
HORSE
POWER ID
1/2 HP - Yellow
1 HP -Purple
CAPACITOR
Second capacitor for
1HP operator ONLY.
Black
Red
MOTOR
ID
MOTOR RED
MOTOR BLUE
J14
J7
SWITCH
TRANSFORMER
J5
COMM
J3
120VAC
J2
MOTOR
WHITE
J18
INPUT
J10
J1
NEUTRAL
OUTLET
MOTOR
J12
WHITE
CONTROL
J6
BLACK
CURRENT
INPUT
SENSOR
J4
HOT
J8
SWITCH
POWER BOARD
SINGLE PHASE
EXPANSION BOARD
PLUG-IN LOOP DETECTOR
Model LOOPDETLM
INTERRUPT LOOP
SHADOW LOOP
AUXILIARY
RELAY 1
EXIT LOOP
Jumper
N.C.
EXIT LOOP
SHADOW LOOP
N.C.
COM
N.O.
ACCESSORY POWER
24 VDC 500 mA Maximum
Yellow
Blue
Black
Red
ALARM
Red
Black
Orange
Orange
TRANSFORMER
24 VAC
24 VAC
COM
COM
MOTOR
120
120
White
ACCESSORY POWER OUTLET
Second motor for 1HP operator ONLY.
Attach to
metal chassis
White
AC POWER SWITCH
Black
Yellow
Orange
These switches determine if the
corresponding photoelectric sensor
or edge sensor will function
for the OPEN or CLOSE cycle.
PHOTOELECTRIC SENSORS
PHOTOELECTRIC SENSORS
or EDGE SENSORS
SINGLE BUTTON CONTROL STATION
3-BUTTON
N.C.
CONTROL
STATION
Jumper
These switches control how the Auxiliary Relays will function.
SWITCH SETTINGS
RELAY 1
1
2
3
OFF
OFF OFF
Relay always off
Relay always off
OFF OFF ON Energizes at open limit
Energizes at open limit
OFF
ON
OFF
Energizes when not at
Energizes when not at
close limit
close limit
AUXILIARY
OFF
ON
ON
Energizes when motor is on
Energizes when motor is on
RELAY 2
ON
OFF
OFF
Energizes 3 seconds prior
Energizes 3 seconds prior
and during gate motion
and during gate motion
ON
ON
OFF
Not used
Not used
ON
OFF
ON
Energizes when gate is
Energizes when gate is
tampered with
tampered with
ON
ON
ON
LEDs will blink cycle count
Not used
SINGLE PHASE WIRING DIAGRAM
Models SL3000UL and CSW200UL
3-BUTTON
CONTROL STATION
INTERRUPT LOOP
or
FIRE
PHOTOELECTRIC SENSORS
DEPARTMENT
for CLOSE cycle
ACCESS CONTROL
DEVICE
OR
Shielded Twisted Pair Cable
(Primary/Secondary link to other gate
operator) Ground the shield of the cable to
the chassis ground of each operator.
SOLENOID LOCK
(Optional)
OR
MAGLOCK
(Optional)
Not Provided
Not Provided
POWER BOARD
Single Phase
MOTOR
ID
MOTOR RED
MOTOR BLUE
J14
J10
MOTOR
CONTROL
CURRENT
SENSOR
J8
Green
Attach to
metal chassis
Earth Ground Rod
CONTROL BOARD
SL3000UL Limit Switch Wiring
CLOSE
9
8 7 6 5 4 3 2 1
Limit Switch
Black
Yellow
Red
4
3
Black
2
Green
1
CSW200UL Limit Switch Wiring
CONTROL BOARD
WIRELESS
EDGE KIT
RPM & LIMITS ALA
SET
8 7 6 5 4 3 2 1
9
Black
Yellow
White
Green
5
4
3
Black
2
Red
1
RED/GREEN
LIGHT FUNCTIONALITY
RELAY 2
Red light
wired to AUX RELAY 1.
AUX RELAY 1 SWITCHES
GATE STATE
1
OFF
2
OFF
3
Red light OFF*
CLOSED
OPENING
Red light ON/FLASH
Red light OFF
OPEN
CLOSING
Red light ON/FLASH
Defined Mid Stop
n/a
Undefined Mid
Red light ON
Stop
Timer more than
Red light OFF
5 seconds
Timer less than
Red light ON/FLASH
5 seconds
* For red light ON when gate is closed, set switch 1 on AUX RELAY 1 to ON
EDGE SENSOR
for CLOSE cycle
PHOTOELECTRIC
EDGE SENSOR
SENSORS
for OPEN cycle
OR
Power Wiring
J7
SWITCH
TRANSFORMER
J5
COMM
J3
120VAC
J2
MOTOR
BROWN
J18
White
INPUT
J1
NEUTRAL
HEATER
OUTLET
J12
WHITE
(Optional Accessory)
J6
BLACK
INPUT
J4
HOT
SWITCH
Black
Red
White
Black
JUNCTION BOX
INCOMING POWER
OPEN
Limit Switch
Blue
NC
NC
NO
NO
Black
C
C
4
3
RPM BOARD
2
1
OPEN Limit Switch (top)
C
NO
NC
CLOSE Limit Switch (bottom)
C
NO
NC
5
4
3
RPM BOARD
2
1
Green light
wired to AUX RELAY 2.
AUX RELAY 2 SWITCHES
OFF
1
ON
2
ON
3
ON
Green light OFF
Green light OFF
Green light ON
Green light OFF
n/a
Green light OFF
Green light ON
Green light OFF
© 2018, LiftMaster
All Rights Reserved
01-39240-5

Advertisement

loading

Summary of Contents for Chamberlain Elite Series

  • Page 1 SINGLE PHASE WIRING DIAGRAM Models SL3000UL and CSW200UL 3-BUTTON CONTROL STATION To reduce the risk of INJURY or DEATH: Jumper • DISCONNECT power BEFORE installing or servicing operator. CONTROL BOARD • Replace ONLY with fuse of same type and rating. EDGE SENSOR INTERRUPT LOOP •...
  • Page 2 SCHÉMA DE CÂBLAGE MONOPHASÉ Modèles SL3000UL et CSW200UL POSTE DE COMMANDE À TROIS BOUTONS Pour réduire le risque de BLESSURES GRAVES, voire MORTELLES: Liaison • DÉCONNECTER l’alimentation AVANT de procéder à l’installation de l’actionneur CARTE LOGIQUE ou à une intervention d’entretien sur celui-ci. •...

This manual is also suitable for:

Csw200ulSl3000ul