System-error log messages

A system-error log is generated only if a Remote Supervisor Adapter II SlimLine is
installed. The system-error log can contain messages of three types:
Information
Warning
Error
Each message contains date and time information, and it indicates the source of
the message (POST/BIOS or the service processor).
Note: The BMC log, which you can view through the Configuration/Setup Utility
program, also contains many information, error, and warning messages.
In the following example, the system-error log message indicates that the server
was turned on at the recorded time.
The following table describes the possible system-error log messages and
suggested actions to correct the detected problems.
v Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved.
v See Chapter 3, "Parts listing, Type 8872 and Type 8874," on page 93 to determine which components are
customer replaceable units (CRU) and which components are field replaceable units (FRU).
v If an action step is preceded by "(Trained service technician only)," that step must be performed only by a
trained service technician.
System-error log message
1.5V Calgary PLL Power Good Fault
78
IBM xSeries 460 Type 8872 and xSeries MXE 460 Type 8874: Problem Determination and Service Guide
Attention:
Do not restart or turn off the server until the update is completed.
page.
Information messages do not require action; they record significant
system-level events, such as when the server is started.
Warning messages do not require immediate action; they indicate
possible problems, such as when the recommended maximum
ambient temperature is exceeded.
Error messages might require action; they indicate system errors,
such as when a fan is not detected.
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
Date/Time: 2002/05/07 15:52:03
DMI Type:
Source: SERVPROC
Error Code: System Complex Powered Up
Error Code:
Error Data:
Error Data:
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
Action
1. Reseat the I/O board.
2. Reseat the microprocessor tray.
3. (Trained service technician only) Replace the PCI-X board.