Serveraid-8I Adapter - IBM 8872 - eServer xSeries 460 Service Manual

Problem determination and service guide
Table of Contents

Advertisement

ServeRAID-8i adapter

The ServeRAID-8i adapter can be installed only in its dedicated connector on the
PCI-X board. The ServeRAID-8i adapter is not cabled to the server and no
rerouting of the SAS cables is required.
To remove the ServeRAID-8i adapter, complete the following steps:
1. Read the safety information that begins on page vii and "Installation guidelines"
2. Turn off the server and peripheral devices, and disconnect the power cords and
3. Remove the top cover (see "Top cover and bezel" on page 113).
4. Grasp the adapter by the plastic handle and pull the adapter from the server.
5. If you are instructed to return the ServeRAID-8i adapter, follow all packaging
To install the replacement ServeRAID-8i adapter, complete the following steps:
1. Touch the static-protective package that contains the adapter to any unpainted
2. Position the ServeRAID-8i adapter so that the metal locking clasp is at the rear
3. Install the top cover (see "Top cover and bezel" on page 113).
112
IBM xSeries 460 Type 8872 and xSeries MXE 460 Type 8874: Problem Determination and Service Guide
ServeRAID-8i
slot
on page 99.
all external cables necessary to replace the device.
instructions, and use any packaging materials for shipping that are supplied to
you.
surface on the outside of the server; then, grasp the adapter by the plastic
handle and remove it from the package.
Attention:
Incomplete insertion might cause damage to the server or the
ServeRAID-8i adapter.
of the server; then, press the ServeRAID-8i adapter firmly into the connector.
ServeRAID-8i

Advertisement

Table of Contents
loading

This manual is also suitable for:

Xseries 460 8872Xseries mxe 460 8874

Table of Contents