Post Beep Codes - IBM 8872 - eServer xSeries 460 Service Manual

Problem determination and service guide
Table of Contents

Advertisement

POST beep codes

A beep code is a combination of short or long beeps or series of short beeps that
are separated by pauses. For example, a "1-2-3" beep code is one short beep, a
pause, two short beeps, and pause, and three short beeps. A beep code other than
one beep indicates that POST has detected a problem. To determine the meaning
of a beep code, see "Beep code descriptions." If no beep code sounds, see
"No-beep symptoms" on page 18.
Beep code descriptions
The following table describes the beep codes and suggested actions to correct the
detected problems.
A single problem might cause more than one error message. When this occurs,
correct the cause of the first error message. The other error messages usually will
not occur the next time POST runs.
Exception: If there are multiple error codes or light path diagnostics LEDs that
indicate a microprocessor error, the error might be in a microprocessor or in a
microprocessor socket. See "Microprocessor problems" on page 42 for information
about diagnosing microprocessor problems.
v Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved.
v See Chapter 3, "Parts listing, Type 8872 and Type 8874," on page 93 to determine which components are
customer replaceable units (CRU) and which components are field replaceable units (FRU).
v If an action step is preceded by "(Trained service technician only)," that step must be performed only by a
trained service technician.
Beep code
1-1-3
1-1-4
1-2-1
1-2-2
1-2-3
1-2-4
14
IBM xSeries 460 Type 8872 and xSeries MXE 460 Type 8874: Problem Determination and Service Guide
Description
CMOS write/read test failed.
BIOS ROM checksum failed.
Programmable interval timer failed.
DMA initialization failed.
DMA page register write/read failed.
RAM refresh verification failed.
Action
1. Reseat the following components:
a. Battery
b. I/O board
2. Replace the components listed in step 1
one at a time, in the order shown, restarting
the server each time.
1. Reseat the microprocessor tray.
2. (Trained service technician only) Replace
the microprocessor tray.
1. Reseat the I/O board.
2. Replace the I/O board.
1. Reseat the I/O board.
2. Replace the I/O board.
1. Reseat the I/O board.
2. Replace the I/O board.
1. Reseat the following components:
a. DIMM
b. Memory card
2. Replace the components listed in step 1
one at a time, in the order shown, restarting
the server each time.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Xseries 460 8872Xseries mxe 460 8874

Table of Contents