IBM 8872 - eServer xSeries 460 Service Manual page 38

Problem determination and service guide
Table of Contents

Advertisement

v Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved.
v See Chapter 3, "Parts listing, Type 8872 and Type 8874," on page 93 to determine which components are
customer replaceable units (CRU) and which components are field replaceable units (FRU).
v If an action step is preceded by "(Trained service technician only)," that step must be performed only by a
trained service technician.
Error code
Description
175
Bad EEPROM CRC#1.
178
System VPD not available.
184
Power-on password damaged.
187
VPD serial number not set.
188
Bad EEPROM CRC #2.
189
An attempt was made to access the server
with an incorrect password.
22
IBM xSeries 460 Type 8872 and xSeries MXE 460 Type 8874: Problem Determination and Service Guide
Action
1. Restart the server.
2. Update the BMC firmware (see "Updating the
firmware" on page 133).
3. Reseat the microprocessor tray.
4. (Trained service technician only) Replace the
microprocessor tray.
1. Restart the server.
2. Update the BMC firmware (see "Updating the
firmware" on page 133).
3. Reseat the microprocessor tray.
4. (Trained service technician only) Replace the
microprocessor tray.
1. Run the Configuration/Setup Utility program,
select Load Default Settings, and save the
settings.
2. Reseat the following components:
a. Battery
b. I/O board
3. Replace the components listed in step 2 one at a
time, in the order shown, restarting the server
each time.
1. Set the serial number by updating the BIOS code
level (see "Updating the firmware" on page 133).
2. Reseat the following components:
a. I/O board
b. Optional Remote Supervisor Adapter II
SlimLine
3. Replace the components listed in step 2 one at a
time, in the order shown, restarting the server
each time.
1. Restart the server.
2. Update the BMC firmware (see "Updating the
firmware" on page 133).
3. Reseat the microprocessor tray.
4. (Trained service technician only) Replace the
microprocessor tray.
Restart the server and enter the administrator
password; then, run the Configuration/Setup Utility
program and change the power-on password.