System Reliability Guidelines; Working Inside The Server With The Power On; Handling Static-Sensitive Devices - IBM 8872 - eServer xSeries 460 Service Manual

Problem determination and service guide
Table of Contents

Advertisement

v When you are finished working on the server, reinstall all safety shields, guards,
v For a list of supported options for the server, see http://www.ibm.com/pc/compat/.

System reliability guidelines

To help ensure proper cooling and system reliability, make sure that:
v Each of the drive bays has a drive or a filler panel installed in it.
v If the server has redundant power, each of the power-supply bays has a power
v There is adequate space around the server to allow the server cooling system to
v You have followed the cabling instructions that come with optional adapters.
v You have replaced a failed fan within 48 hours.
v You have replaced a hot-swap drive within 2 minutes of removal.
v You do not run the server without the air baffle installed. Operating the server
v Microprocessor sockets 2, 3, and 4 each always contain either a microprocessor
v For redundant and hot-swappable operation, the power supplies are connected to

Working inside the server with the power on

Attention:
the server is powered-on might cause the server to halt, which could result in the
loss of data. To avoid this potential problem, always use an electrostatic-discharge
wrist strap or other grounding system when working inside the server with the
power on.
The server supports hot-swap devices and is designed to operate safely while it is
turned on and the cover is removed. Follow these guidelines when you work inside
a server that is turned on:
v Avoid wearing loose-fitting clothing on your forearms. Button long-sleeved shirts
v Do not allow your necktie or scarf to hang inside the server.
v Remove jewelry, such as bracelets, necklaces, rings, and loose-fitting wrist
v Remove items from your shirt pocket, such as pens and pencils, that could fall
v Avoid dropping any metallic objects, such as paper clips, hairpins, and screws,

Handling static-sensitive devices

Attention:
To avoid damage, keep static-sensitive devices in their static-protective packages
until you are ready to install them.
100
IBM xSeries 460 Type 8872 and xSeries MXE 460 Type 8874: Problem Determination and Service Guide
labels, and ground wires.
supply installed in it.
work properly. Leave approximately 50 mm (2 in.) of open space around the front
and rear of the server. Do not place objects in front of the fans. For proper
cooling and airflow, replace the server cover before turning on the server.
Operating the server for extended periods of time (more than 30 minutes) with
the server cover removed might damage server components.
without the air baffle might cause the microprocessor or microprocessors to
overheat.
baffle or a microprocessor and heat sink.
200-240 V ac.
Static electricity that is released to internal server components when
before working inside the server; do not wear cuff links while you are working
inside the server.
watches.
into the server as you lean over it.
into the server.
Static electricity can damage the server and other electronic devices.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Xseries 460 8872Xseries mxe 460 8874

Table of Contents