IBM 8872 - eServer xSeries 460 Service Manual page 139

Problem determination and service guide
Table of Contents

Advertisement

Air baffle
1. Read the safety information that begins on page vii and "Installation guidelines"
on page 99.
2. Turn off the server and peripheral devices, and disconnect the power cords
and all external cables necessary to replace the device.
3. Remove the top cover and bezel (see "Top cover and bezel" on page 113).
4. Remove all fans (see "Hot-swap fan" on page 105).
5. Remove the memory cards (see "Removing and replacing a memory card" on
page 108).
6. Lift the microprocessor-tray release latch.
7. Open the microprocessor-tray levers.
Attention:
The microprocessor tray is heavy. Pull the tray partially out of the
server, and then reposition your hands to grasp the body of the tray, before
pulling out the tray the rest of the way.
8. Remove the microprocessor tray.
9. Press in on the release latches on each side of the tray; then, pull the tray out
the rest of the way.
10. Lift the air baffle out of the microprocessor tray.
11. Open the heat sink-release lever and remove the heat sink.
Heat sink
Microprocessor
Chapter 4. Removing and replacing server components
Microprocessor
baffle
VRM 4
123