Release tabs
Guide channels
6. Pull out the two blue pushpins.
7. Squeeze the two blue release tabs.
8. Lift the SCSI backplane out of the server slightly; then, disconnect the power
cable and remove the backplane.
9. Connect the power cable to the replacement backplane.
10. Slide the backplane into the two guide channels.
Note: The cables from steps 4 on page 74 and 5 on page 74 will be routed
over the top of the backplane after the backplane is installed.
11. Align the two slots in the backplane assembly onto the two guide tabs; then,
press firmly until the blue tabs latch. The backplane assembly will snap into
place.
12. Reconnect the cables that were disconnected in step 4 on page 74 and step 5
on page 74.
Note: Route cables into the cable channel (in between the fans). Do not allow
any cables to catch on any metal protrusions.
Chapter 5. FRU information (service only)