7. Connect any required cables to the adapter.
8. If you have other options to install or remove, do so now; otherwise, go to

Removing a PCI or PCI-X adapter

To remove an adapter, complete the following steps:
1. Complete steps 1 on page 35 through 3 on page 35.
2. Open the blue adapter guide (see step 6a on page 35) and the orange adapter
3. If the adapter has any internal cables, disconnect them.
4. Carefully grasp the adapter by its top edge or upper corners and pull the
5. If the adapter slot will remain empty, close the blue adapter guide and the
6. If you have other options to install or remove, do so now; otherwise, go to

Installing a hot-swap hard disk drive

The following notes describe the types of hard disk drives that your server supports
and other information that you must consider when installing a hard disk drive:
v The server supports up to six 26 mm (1-inch), 3.5-inch, hot-swap hard disk drives
v Each hot-swap drive is in a tray, which has a green activity LED and an amber
v Before you install a hot-swap hard disk drive, take the following actions:
Complete the following steps to install a hard disk drive:
1. Read "Safety information" on page 147 and "Installation guidelines" on page 29.
2. Remove the filler panel and air baffle from one of the empty hot-swap bays, if
36
IBM xSeries 365 Types 8861, 8862: Hardware Maintenance Manual and Troubleshooting Guide
Attention:
When you install an adapter, avoid touching the components
and gold-edge connectors on the adapter. Be sure the adapter is correctly
seated in the connector. Incorrectly seated adapters might cause damage to
the I/O board or to the adapter.
f. Press the adapter firmly into the adapter connector.
g. Push down on the blue adapter guide to stabilize the adapter.
h. Close the tab; then, push down on the blue adapter retention latch until it
clicks into place, securing the adapter.
"Completing the installation" on page 58.
retention latch (see step 6b on page 35).
adapter up and out of the server.
orange adapter retention latch, and replace the expansion slot cover.
"Completing the installation" on page 58.
in the hot-swap bays.
status LED in the upper-right corner. The activity LED flashes when the drive is
active; the status LED is lit if the drive has an error. Each hot-swap drive has a
single-connector-attached (SCA) connector, which connects directly into the
hot-swap SCSI hard disk drive backplane. The backplane controls the SCSI IDs
for the hot-swap drives.
– Inspect the drive tray for any signs of damage.
– Make sure that the drive is installed in the tray correctly.
– If your server has an optional RAID adapter installed, see the documentation
that comes with the adapter for information about installing a hard disk drive.
present.
Attention:
To maintain proper system cooling, do not operate the server for
more than 10 minutes without either a drive or filler panel installed in each bay.