Note: See Chapter 7, "Parts listing, Types 8861, 8862," on page 139 to determine which components are
replaceable by the customer and which components must be replaced by an IBM field service technician.
Error code/symptom
166-051-000 System Management: Failed
(Unable to communicate with ASM. It may
be busy. Run the test again.)
166-060-000 System Management: Failed
(Unable to communicate with ASM. It may
be busy. Run the test again.)
166-070-000 System Management: Failed
(Unable to communicate with ASM. It may
be busy. Run the test again.)
166-198-000 (BIOS cannot detect ASM.
Reseat ASM adapter in correct slot) (ASM
restart failure. Unplug and cold boot server
to reset ASM)
166-201-000 (ISMP indicates I2C errors
on bus X)
166-201-001 (ISMP indicates I2C errors
on bus P)
166-201-002 (ISMP indicates I2C errors
on bus I)
166-201-003 (ISMP indicates I2C errors
on bus C)
98
IBM xSeries 365 Types 8861, 8862: Hardware Maintenance Manual and Troubleshooting Guide
FRU/action
1. Flash latest levels of firmware (BIOS, service processor,
diagnostics)
2. Rerun diagnostic test.
3. Correct other error conditions (including failed system management
tests and items logged in Remote Supervisor Adapter system error
log and retry.)
4. Disconnect all server and option power cords from server, wait 30
seconds, reconnect, and retry.
5. Remote Supervisor Adapter.
1. Flash latest levels of firmware (BIOS, service processor,
diagnostics)
2. Rerun diagnostic test.
3. Correct other error conditions (including failed system management
tests and items logged in Remote Supervisor Adapter system error
log and retry.)
4. Disconnect all server and option power cords from server, wait 30
seconds, reconnect, and retry.
5. Remote Supervisor Adapter.
1. Flash latest levels of firmware (BIOS, service processor,
diagnostics)
2. Rerun diagnostic test.
3. Correct other error conditions (including failed system management
tests and items logged in Remote Supervisor Adapter system error
log and retry.)
4. Disconnect all server and option power cords from server, wait 30
seconds, reconnect, and retry.
5. Remote Supervisor Adapter.
1. Rerun diagnostic test.
2. Correct other error conditions (including other failed system
management tests and items logged in Remote Supervisor Adapter
system error log) and retry.
3. Disconnect all server and option power cords from server, wait 30
seconds, reconnect, and retry.
4. Remote Supervisor Adapter.
5. I/O board.
v I/O board
1. Power backplane
2. I/O board
3. Microprocessor tray assembly
v I/O board
1. Microprocessor tray assembly
2. I/O board