Note: See Chapter 7, "Parts listing, Types 8861, 8862," on page 139 to determine which components are
replaceable by the customer and which components must be replaced by an IBM field service technician.
Service Processor message
5V Planar Fault
Application Posted Alert to ASM
Cable: Media cable not detected
Cable: SCSI I2C cable not detected
Continuous 3.3V over recommended value
Continuous 3.3V under recommended value
CPU X Over Temperature
DASD X over recommended temperature
Environmental Monitor firmware needs
updating. No environmental information
currently available.
Environmental Monitor Flash Update Failed
Environmental Monitor not responding
Environmental Monitor RAM Error
Environmental Monitor ROM Error
Ethernet Data Rate modified from <value1>
to <value2> by user <USERID>
Ethernet Duplex setting modified from
<value1> to <value1> by user <USERID>
Ethernet interface <value> by user <USERID> v Information only
Ethernet locally administered MAC address
modified from x:x:x:x:x:x
Ethernet MTU setting modified from x to y by
user <USERID>
Failure reading I2C device. Check devices on
bus X
110
IBM xSeries 365 Types 8861, 8862: Hardware Maintenance Manual and Troubleshooting Guide
FRU/action
v I/O board assembly
v Information only
1. Verify IDE media cable is properly connected.
2. Media interposer card.
1. Verify SCSI cables are properly connected.
2. SCSI backplane.
v I/O board assembly
v I/O board assembly
1. Check all fans and remove any obstacles from the path of
airflow.
2.
Verify room temperature is within recommended range.
3.
Verify microprocessor heat sinks are properly seated.
1. Check all fans and remove any obstacles from the path of
airflow.
2. Verify room temperature is within recommended range.
v Run the latest version of the Remote Supervisor Adapter
Firmware Update Utility.
v Run the latest version of the Remote Supervisor Adapter
Firmware Update Utility.
1. Run the latest version of the Remote Supervisor Adapter
Firmware Update Utility.
2. Replace appropriate board.
1. Run the latest version of the Remote Supervisor Adapter
Firmware Update Utility
2. Replace appropriate board.
1. Run the latest version of the Remote Supervisor Adapter
Firmware Update Utility
2. Replace appropriate board.
v Information only
v Information only
v Information only
v Information only
v Run diagnostics.