Note: See Chapter 7, "Parts listing, Types 8861, 8862," on page 139 to determine which components are
replaceable by the customer and which components must be replaced by an IBM field service technician.
Service Processor/RXE-100 message
PCI Expansion Unit X Side A or B: +5V
Power Not Adequate
PCI Expansion Unit X Side A or B: +5v under
recommended voltage
PCI Expansion Unit X Side A or B: +5v under
voltage
PCI Expansion Unit X Side A or B: -12v over
recommended voltage
PCI Expansion Unit X Side A or B: -12v over
voltage
PCI Expansion Unit X Side A or B: -12v
under recommended voltage
PCI Expansion Unit X Side A or B: -12v
under voltage
PCI Expansion Unit X Side A or B: Chipset
Power-Good Fault
PCI Expansion Unit X Side A or B:
Continuous +3.3v over voltage
PCI Expansion Unit X Side A or B:
Continuous +3.3v under voltage
PCI Expansion Unit X Side A or B:
Continuous +5v over voltage
PCI Expansion Unit X Side A or B:
Continuous +5v under voltage
PCI Expansion Unit X Side A or B:
Environmental Monitor Flash Update Failed
PCI Expansion Unit X Side A or B:
Environmental Monitor RAM Error
PCI Expansion Unit X Side A or B:
Environmental Monitor ROM Error.
PCI Expansion Unit X Side A or B: Expansion
system over recommended ambient
temperature
PCI Expansion Unit X Side A or B: Failure
reading an I2C device
118
IBM xSeries 365 Types 8861, 8862: Hardware Maintenance Manual and Troubleshooting Guide
FRU/action
v Remove adapters one at a time.
1. Check slot 5 or 6 for short or bent pins.
2. Power supply
1. Check slot 5 or 6 for short. Check pins between PCI and
DMC card.
2. Power supply
v Power supply.
v Power supply.
1. Check pins between PCI and DMC card and all slots.
2. Power supply
1. Check pins between PCI and DMC card and all slots.
2. Power supply
v I/O board.
v Power supply.
1. Check pins between PCI and DMC card.
2. Power supply
v Power supply.
1. Check pins between PCI and DMC card.
2. Power supply
1. Run the latest version of the Remote Supervisor Adapter
Firmware Update Utility.
2.
Replace appropriate board.
1. Run the latest version of the Remote Supervisor Adapter
Firmware Update Utility.
2.
Replace appropriate board.
1. Run the latest version of the Remote Supervisor Adapter
Firmware Update Utility
2.
Replace appropriate board.
1. Check all fans and remove any obstacles from the path of
airflow in RXE-100
2. Verify room temperature is within recommended range.
1. Replace power backplane.
2. Replace power supply.
3. Replace DMC card.
4. Board.