Tandberg Data FC420 Bridge Option User's Guide
Document T6423053-01, Ver. 1, Rel. 0
November 2002
Command
LogEvent
MaxEnclTempAlrm
Menu
MinEnclTempAlrm
OEMConfigFile
ParityLog
Performance
20
Description
Sets the switches which control the
filtering performed when logging
events. The switches have the
following meanings and settings:
[enabled | disabled] switch: controls
whether or not events logging is
enabled or disabled.
[subsystem] switch: same as switch for
DispEvent in previous section
[event_level] switch: same as switch
for DispEvent in previous section
[status] switch: same as switch for
DispEvent in previous section
Sets/displays the maximum enclosure
temperature alarm of the unit in
degrees C (5-40 degrees C).
Enables/disabled the menu interface.
Entering the command alone without
parameters toggles the current state.
Sets/displays the minimum enclosure
temperature alarm of the unit in
degrees C (5-40 degrees C).
Reports the name (i.e., the contents of
the first record) of the OEM
configuration file stored in persistent
memory. This file is used to override
the factory default configuration of the
FC420 Fibre bridge.
Resets/displays the parity error
statistics for the Fibre bridge. The get
command displays the statistics; the
set command resets the statistic
counters to zero.
Returns the performance data for a
user-specified Fibre port.
FC420 Services Software Commands
Default
Syntax
set logevent [enabled |
disabled] | [[subsystem]
[event_level] [status]]
get logevent
disabled
3Fh
3Fh
all
70°C
set maxencltempalrm [5 - 40]
get maxencltempalrm
menu <[enabled | disabled]>
0°C
set minencltempalrm [5 - 40]
get minencltempalrm
get oemconfigfile
set paritylog clear
get paritylog
get performance <fp>