NETWORK 2
NETWORK 1
A
B 0V
A
B 0V
DOORS
A
B
0V
SERIAL
RX
TX
0V
ACTpro 4000
ACT Nework Interface Card
RS485 232 Interface
RS485
LED2
Line 2
Line 1
C 1 2
C 1 2
~AC~
+BAT-
1.
Connect the ACT modem to the PC and install modem driver.
2.
In ACTWin pro, Click on the Locations and Connections icon on the toolbar.
3.
Configure the remote site name in the Location Name.
4.
Select the Type of Connection as Modem.
5.
Enter the remote sites' telephone number.
6.
Select the newly installed modem as the Dialup Modem.
7.
Set up remote controller(s) in the Controller View. Set the location as the remote site name.
6.
The controller(s) will appear under the remote site name in the System View window.
7.
Double click on the telephone icon beside the remote site name in System View window.
8.
Modem will now contact remote Site and connect to the controller(s).
9.
To finish the call, click the disconnect button on ACTWin pro

ACT Modem Configuration

Direct Connection from Modem to Controller
Max cable length is 5m using standard alarm cable
or 30m using twin twisted-pair (use 0V in each pair)
Modem Connection for ACT Network
RS232
PORT
Converter
LED3
Line 4
Line 3
C 1 2
C 1 2
ACTWin pro Setup for Modem Operation
Connections for
25 Way male Connector
RX = Pin 3
TX = Pin 2
0V = Pin 7
7
3 2
DB25 Male
(Rear View)
1. Connect Network Modem Cable to ACT Network card and Modem
2. In ACTpro 4000 Communications Menu set the controller Address
3. Controller(s) now ready to receive calls
47
1. Connect Modem Cable directly
to ACTpro 4000 and Modem
2. In Communications Menu Set:
Address = 1
3. Controller is now ready to receive calls
DO = Pin 2
DI = Pin 3
C = NC
SCN = Pin 7
7
3 2
Connections for
25 Way male Connector
DB25 Male
(Rear View)