ACTpro 4000 Operating Instructions
__________________________________________________________________________
The System Settings menu allows the installer to access a number of different configuration
menus controlling different aspects of the setup of the controller. Pressing the
the setting of a displayed option.
Operation
This menu allows the installer to select or de-select a number of options relating to the default
operation of the controller.
• The PIN Only option allows reader-less operation using PIN codes that are directly
entered on the keyboard (or on an external keypad). 60,000 PIN codes supported.
• The Learn option allows users to use randomly coded cards. Almost any card with valid
ISO track 2 data may be used (for example bankcards) as well as some types of wiegand
card.
• The Exit PINs option is requires PIN codes to be entered before the user is allowed to
exit.
• The User Limiting option will prevent access to tracked users when the user limit is
reached.
• The One-To-One option allows any card number to be captured and assigned to any of
the 60,000 users.
• The Multiple option allows users to have more than one card on the system.
• The TnA Terminal option allows the keypad to be used as a Time and Attendance
terminal. When a card is read from door 1 or door 2, the users name is displayed and they
can choose to clock-in or clock-out.
Display
• The Backlight option forces the keypad to be permanently illuminated, overriding the
default automatic operation, which is to operate only when a user menu has been entered.
• The Keypad Beep option forces the keypad to make a short beep in response to any key
being pressed. This option is selected by default.
• The Show Status option enables the displaying of continuous door status on the display.
This option is enabled by default.
• The Show Events option enables the displaying of events on the display as they occur.
This option is enabled by default.
• The Tech Bleep option specifies that the ACTpro 4000's onboard buzzer will sound
intermittently if a technical fault (mains, tamper or door offline) condition exists.
Language
The ACTpro 4000 display supports the following languages English, Polish, French, Spanish,
Dutch and Italian. The language is selected from this menu.
__________________________________________________________________________________