ACTpro 4000 Operating Instructions
__________________________________________________________________________
• The Door Ajar alarm occurs when the door has remained open for longer than the
duration programmed into the door ajar timer. The AUX relay is activated while the door
remains open.
• The Duress alarm occurs whenever a duress code is entered during Pin & Card
operation. The duress code is the PIN code for that user with the last digit advanced by
one.
• The Door Open alarm activates the AUX relay whenever the door is open.
• The Access Granted alarm activates the AUX relay for the programmed duration
whenever a valid card is presented at an entry reader.
• The Exit Granted alarm activates the AUX relay for the programmed duration whenever a
valid card is presented at an exit reader
• The Access Denied alarm activates the AUX relay for the programmed duration
whenever an invalid card is presented to an entry reader.
• The Exit Denied alarm activates the AUX relay for the programmed duration whenever an
invalid card is presented to an exit reader.
• The Relay Follow alarm activates the AUX relay whenever the Main relay is active.
• The Arm Intruder option allows the AUX relay to be used to ARM/DISARM external alarm
panels. See end of manual for more information.
• The Break Glass option activates the AUX relay when a break glass event is detected on
the door.
Timers
The door timers menu allows the installer to program the time delays for the relay, AUX
output, open collector outputs OP2 and OP3 and the door ajar alarm time. Each timer may be
programmed with duration from 1 to 999 seconds. The relay time may be programmed to 0
seconds, which will operate the relay for a quarter of a second approximately. This can be
used for turnstile applications. Door Stations will support a maximum duration of 127
seconds.
This Menu allows the user to set up a number actions that will occur at requested times. The
time that a particular action should occur is set up in a time zone and then assigned to that
action. When the time time zone is in force, then the assigned action occurs for that duration.
Action
Unlock Door
Lock Door
__________________________________________________________________________________
Timed Actions
For the duration of the assigned time zone, the door remains
unlocked. The Green LED on the Reader will Flash.
For the duration of the assigned time zone, the door remains locked.
The Red LED on the Reader will Flash.
24
What Happens.