Control Door; Lock Door; Unlock Door; Normalise Door - ACT ACTPRO 4000 Operating And Installation Instructions

Access control system
Hide thumbs Also See for ACTPRO 4000:
Table of Contents

Advertisement

ACTpro 4000 Operating Instructions
1.00
__________________________________________________________________________
The event types that can be filtered are access granted, access denied, alarms (mains fail,
tamper etc.), door events (exit button pressed etc.) and others. The 0 key advances to each
event type and the
key enables or disables the displayed event type.
The events may also be filtered out on certain doors. Normally all doors are allowed, but the
user may prevent certain doors from reporting events.

Control Door

The Control Door menu allows the operator to control the door or externally connected
equipment such as lighting or heating. The door failsafe option may be considered to be
disabled for the following control door examples.

Lock Door

The Lock Door function causes the door relay to be de-energized. The bottom line of the
display will show "Door Locked" and the red LED on the reader will flash. All subsequent
cards will be rejected until the door is unlocked or returned to its normal state.

Unlock Door

The Unlock Door function causes the door relay to be energized. The bottom line of the
display will show "Door Unlocked" and the green LED on the reader will flash.

Normalise Door

The Normalise Door function causes the door relay to be de-energized and the door to
return to its normal state. The LED on the reader stops flashing and all subsequent operation
will be the normal response to card activity.

Pass Door

The Pass Door function causes the door relay to be energized for the programmed period of
time. This may be used to grant access to a person waiting outside the door.

AUX output on

The AUX output on function causes the auxiliary output relay to be energized. It will remain
energized until the output is explicitly switched off. The output may be used to control
externally connected equipment such as lights or heating.

AUX output off

The AUX output off function causes the auxiliary output relay to be de-energized. The output
may be used to control externally connected equipment such as lights or heating.

User Tracking

The user tracking option allows the controller to remember which users are in or out of the
defined area. If anti-passback or timed anti-passback doors are assigned, then these define
__________________________________________________________________________________
11

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents