ACT ACTPRO 4000 Operating And Installation Instructions page 25

Access control system
Hide thumbs Also See for ACTPRO 4000:
Table of Contents

Advertisement

ACTpro 4000 Operating Instructions
__________________________________________________________________________
PIN Length
The length of PIN codes used in PIN Only and PIN & Card modes may be set between 4 and
9 digits. If a PIN length greater than six is set, then the length of the operator and installer
codes will increase to this length. (Leading zeros added to PIN).
Fire Doors
This function allows a group of doors (or all doors) to be configured for fire override. A 0Volt
signal from a fire alarm (or other) system is applied to the AUX input on door 1. This
maintains normal operation. When the 0Volt signal is removed, the selected doors are held
open until the 0 Volt signal is re-applied. Typically, a normally-closed relay on the fire panel,
with the common connected to 0 Volts, is used for this purpose. Please note that this facility is
present for convenience only, it does not remove the need to have an alternate mechanical
means of escape.
User Tracking
• Doors may be defined as Perimeter doors by pressing the
is displayed. Those not defined as a Perimeter door are displayed as -. Users that enter
through a perimeter door are tracked but not restricted. Tracking of a user means it is
logged if the user is in the tracking area or not. Entering through any perimeter doors logs
the user into the area. Exiting any perimeter door logs the user out of the area. Note: If
either Anti-passback or Timed Anti-passback doors are defined then perimeter
doors are ignored.
• Doors may be defined as Anti-passback doors by pressing the
number is displayed. Those not defined as Anti-passback doors are displayed as -. The
Anti-passback doors define the tracking area. Users are allowed entry to the area only if
they have previously exited.
• Doors may be defined as Timed Anti-passback doors by pressing the
door number is displayed. Those not defined as Timed Anti-passback doors are
displayed as -. Timed Anti-passback doors define the tracking area. Users are allowed
entry to the area only if they have previously exited or after the Timed Anti-passback
period has expired. The Timed Anti-passback period is defined on a user group basis.
Note: If a door is specified as an Anti-passback door and as a Timed Anti-passback
door, then the door will operate as a Timed Anti-passback door.
• Internal Doors are doors that are inside the perimeter of the installation. Access is denied
on these doors if the cardholder has not already entered through the perimeter or Anti-
passback doors.
• Tracking Reset is used to auto-reset (log all users out) at a specific time each day, or
may be reset manually. In addition users may be individually logged in or out. This is
recorded in the system log.
__________________________________________________________________________________
key so that the door number
21
1.00
key so that the door
key so that the

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents