ACT ACTPRO 4000 Operating And Installation Instructions page 53

Access control system
Hide thumbs Also See for ACTPRO 4000:
Table of Contents

Advertisement

Upto 4 IO Modules maybe connected a single ACT Controller.
The IO Modules share the same network as Door stations (DS100s).
Therefore a controller may support up to 16 Doors and 4 IO Modules.
If the Mains Present or Door
Contact inputs are not used,
they should be linked to 0V
SETTING IO MODULE ADDRESS
IO Module address is set via the DIP
switches. Up to 4 IO Modules maybe
connected to a ACTpro 2000 controller.
1 2 3 4 5 6 7 8
IO Module Addr 1:
On
1 2 3 4 5 6 7 8
IO Module Addr 2:
On
1 2 3 4 5 6 7 8
IO Module Addr 3:
On
1 2 3 4 5 6 7 8
IO Module Addr 4:
On
ACTpro IOM IO Module Installation
OP3
OP4
NC
C
NO
NC
C
NO
TAMPER
MAINS
1 2 3 4 5 6 7 8
PRESENT
+
12V DC
-
On
OP5
OP6
To next Door
or IO Module
FACTORY DEFAULT
This unit should be reset to its
factory default condition before
installation. To do this, power
the unit up with ALL switches in
the OFF position. The two LED's
will illuminate for about 2 sec.
The correct switch settings may
then be set.
Installation of an IO Module requires the following
(1) Wiring Inputs and Outputs.
(2) Providing 12V Power.
(3) Wiring IO Module A,B and 0V RS485 signals to the Controller.
(4) Setting the IO Module address
All Configuration of Input/Output Operation is performed from ACTwin
INPUTS:
All 8 inputs may be supervised (enabled from
ACTWin software). Supervised inputs maybe
in one of 4 states, Normal,Active,Short or Open
circuited. Supervised inputs required the installer to
OP7
OP8
provide 2 resistors per Supervised input as shown
below.
A OV
B
TX
RX
A/B/OV RS485 WIRING
Total Length max 1.4km
Network cable use either:
(1)Single shielded twisted pair, Belden 9501 or similar.
(2)CAT5 Cable: A/B must use the same twisted pair.
LED Functionality:
Red LED indicates the status of communications with the Controller.
While online to the controller the Red LED will flash rapidly.
If there is a problem it will flash slowly (about once a second).
Green LED will flash if an event occurs on the IO Module.
4k7
IP1
4k7
0V
ACT4000
NETWORK 1
A
A
B
B
0V
Shield