LED Functionality:
Red LED indicates the status of communications with the Controller.
While online to the controller the Red LED will flash rapidly.
If there is a problem it will flash slowly (about once a second).
Green LED will flash if an event occurs on the ACTpro200.
AC AC
Fuse OP2 Blown
Fuse OP1 Blown
Fuse OP1
Fuse OP2
Press to
connect batteries
12V 0V
OUTPUT 1
OUTPUT 2
Battery 1 - Backup for
Output 1 and PCB
*Always connect Battery 1.
4
5
6
7
8
Door
Address
03 OFF OFF OFF ON
ON
04 OFF OFF ON
OFF OFF
05 OFF OFF ON
OFF ON
06 OFF OFF ON
ON
OFF
07 OFF OFF ON
ON
ON
08 OFF ON
OFF OFF OFF
09 OFF ON
OFF OFF ON
10 OFF ON
OFF ON
OFF
11 OFF ON
OFF ON
ON
12 OFF ON
ON
OFF OFF
13 OFF ON
ON
OFF ON
14 OFF ON
ON
ON
OFF
15 OFF ON
ON
ON
ON
16 ON
OFF OFF OFF OFF
Example:
When the dipswitch is set to 3, Door 1 is set to Address 3 and Door 2 is set to Address 4.
When the dipswitch is set to 4, Door 1 is set to Address 4 and Door 2 is set to Address 5.
ACTpro 200 Installation
2 Door Controller and Monitored Power Supply
DISCONNECT BEFORE MAINTENANCE
Secondary AC Fuse
EXT LED
5A 250VAC
5A 30VDC
1 2 3 4 5 6 7 8
BATTERY 1
BATTERY 2
On
12V
0V
Battery OK LEDs
Battery 2 - Backup for Output 2
Monitoring for battery 2 can be disabled
by setting dipswitch 3 to ON
*Connect Red to Battery positve
Black to Battery negative
FACTORY DEFAULT
This unit should be reset to its
factory default condition before
installation. To do this, power
the unit up with ALL switches in
the OFF position. The two LED's
will illuminate for about 2 sec.
The correct switch settings may
then be set.
WARNING:
MAINS VOLTAGE
NO
C NC NO C NC
TAMPER
5A 250VAC
5A 30VDC
5A 250VAC
5A 30VDC
NC
C NO NC C NO
Entry/Exit Reader
Important !
Always Place Varistor
Across Lock Terminals
This illustration shows wiring
for a normally energised
lock. If a normally de-energised
lock is required, use the
N/O relay contacts.
Technical Specifications
Mains Voltage
230Vac +10% -15%
Frequency
47-63 Hz
Mains Fuse
630mAmp
Secondary AC Fuse
3.75 Amp Th Fuse
Fuse OP1
1.25 Amps Quick
Fuse OP2
1.25 Amps Quick
Ripple Voltage
<200mV
46
NETWORK
DOOR 1
Connections
Total Length max 1.4km
Belden 9502 or equiv.
Cable: 8 Core Screened
Belden 9504 or equiv
Max length:
30m from +5V
100m from +12V
White
Green
Blue
Red
Black
Brown
Yellow
Orange
For Clock and Data Readers, wire exit
reader in parallel but do not connect
to SENSE.
For Wiegand Readers, wire DATA0 of
the exit reader to SENSE.
ACTWinPro users must tick Mains
Fault Reporting in the door view
ACTpro 4000
DOORS
A
A
B
B
0V
Shield
OP3
OP2
0V
AUX
INPUT
DC2
PB2
A
DOORS
B
NETWORK
0V
OP3
OP2
0V
DOOR 2
AUX
Connections
INPUT
DC2
PB2
SENSE
CLOCK / DATA 1
DATA / DATA 0
+5V or +12V
0V
RED
GREEN
(Buzzer Control)