ACTpro 4000 Operating Instructions
__________________________________________________________________________
Remote Doors
This menu is where additional door stations are configured as extra doors on the ACTpro
4000 controller. The new door (Door 3 to 16) is selected using the 0 key and the current
status of the door is displayed on the bottom line of the LCD. The
enable or disable the door:
1) To enable, select a
Disabled door
2) To disable, select an
Enabled door
If a non-existent or incorrectly addressed door is enabled, the door will be polled for a short
while, then the status will be displayed as Door Offline.
IO Module
The IOM (Input/Output Module) is wired to the controller on the same RS-485 network as the
DS100 Door stations. The IOM are addressed using the DIP switches on the PCB. The IOMs
may be given any address in the range 1 to 4. No configuration of the IOM is possible from
the ACTpro 4000. All configuration can only be performed from ACTWin pro. However the
IOM may be enabled from this menu which allows the communications between the ACTpro
4000 and the IOM to be tested without the need for ACTWin pro.
No Hist. Log
This option suppresses the reporting of events occurring while offline in slave mode only.
Normally when the controller is operating in slave mode, events are logged locally if the
controller is offline, and are transmitted to the PC when communications are restored.
Print All
This option selects real-time printing to an attached serial printer. Each event is time stamped
and printed immediately on the printer. Real-time printing will be temporarily suspended while
a full log printout requested from the operator menu is in progress.
Set Encryption
A password consisting of a 10 digit number may be programmed into the controller to prevent
unauthorized access from remote ACTWin pro users. Ensure this password matches the
encryption key used by ACTWin pro.
ACTpro 4000 supports connection to a Local Area Network (LAN) using Twisted-pair
Ethernet (100BASE-T or 10BASE-T) via a standard RJ-45 connector. The ACTpro 4000
supports the TCP/IP networking protocol for communications with ACTWin pro / Lite.
__________________________________________________________________________________
Door 3
0 for next door
Disabled
Door 3
0 for next door
Door Normal
TCP/IP Settings
26
 key may then be used to
to enable door
to disable door