ACT1000/2000 Operating Instructions
ACT Recommend the Epson LQ-300:
Wiring between Printer & Controller: Controller
Printer settings:
CHARACTER TABLE
SKIP OVER PERFORATION
GRAPHIC PRINT DIRECTION
AGM
INTERFACE
BIT RATE
STATE REPLY
FILTER LOG (ACT 2000 ONLY)
The Filter Log function allows the user to prevent certain events from being entered on the system
log. Normally all events are logged, but to prevent ACTWinPro from having to store a lot of
information on a large installation, some events may be filtered out.
The event types that can be filtered are access granted, access denied, alarms (mains fail, tamper
etc.), door events (exit button pressed etc.) and others. The 0 key advances to each event type, and
the ✔ key enables or disables the displayed event type.
The events may also be filtered out on certain doors. Normally all doors are allowed, but the user
may prevent certain doors from reporting events.
The Control Door menu allows the operator to control the door or externally connected equipment
such as lighting or heating.

LOCK DOOR

The Lock Door function causes the door relay to be de-energized. The bottom line of the display
will show "Door Locked" and the red LED on the reader will flash. All subsequent cards will be
rejected until the door is unlocked or returned to its normal state.

UNLOCK DOOR

The Unlock Door function causes the door relay to be energized. The bottom line of the display
will show "Door Unlocked" and the green LED on the reader will flash.

NORMALISE DOOR

The Normalise Door function causes the door relay to be de-energized and the door to return to
its normal state. The LED on the reader stops flashing and all subsequent operation will be the
normal response to card activity.

PASS DOOR

The Pass Door function causes the door relay to be energized for the programmed period of time.
This may be used to grant access to a person waiting outside the door.
0v TX RX
0V ............................PIN 7
TX............................PIN 3
RX ..........................PIN 20
PC850
PAGE LENGTH OF TRACTOR 11 INCHES
OFF
AUTO TEAR OFF
BI-D
SOFTWARE
OFF
AUTO LINE FEED
SERIAL DATA LENGTH
9600BPS PARITY BIT
OFF

Control Door

8
Software Version 4.00-00
Printer
SERIAL (25 way connector)
OFF
ESC/P2
OFF
8 BITS
NONE