Calibrating The Video Fader - Edirol V-8 Owner's Manual

8-channel video mixer
Hide thumbs Also See for V-8:
Table of Contents

Advertisement

Calibrating the Video Fader

Because of extended use or transportation, you may find that 100% of the image is not output even though you've moved
the video fader all the way toward bus A or bus B. If this occurs, proceed as follows to calibrate the video fader.
* You must be sure to perform the video fader calibration after installing the V-4CF crossfader (sold separately).
1
Set the video fader to the bus A position.
First, you should perform the calibration for the bus A position.
2
Press the [MENU] button to access the menu, and choose "Utility."
3
Use the [
] [
4
Make sure that the display indicates "V Fader [A] Set [ENTER] SW," and press the [ENTER]
button.
Calibration will be automatically performed for the bus A position, and you will return to the previous screen.
5
Move the video fader to the bus B position.
Next, you need to perform the calibration for the bus B position.
6
Use the [
] [
7
Make sure that the display indicates "V Fader [B] Set [ENTER] SW," and press the [ENTER]
button.
Calibration will be automatically performed for the bus B position, and you will return to the previous screen.
8
Press the [MENU] button several times to close the menu.
Press the [MENU] button to access the menu.
Use the [
Press the [ENTER] button to confirm your selection.
] buttons to select "Video Fader Calibrate A," and press the [ENTER] button.
] buttons to select "Video Fader Calibrate B," and press the [ENTER] button.
Adjusting the Video Fader
] [
] buttons to select "Utility."
(continued)
77

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents