MIDI Implementation
(continued)
2. MIDI messages transmitted from

MIDI OUT

* If MIDI Thru is ON, MIDI messages received at MIDI IN are re-transmitted
without change from MIDI OUT.
* If MIDI Thru is ON, messages from the V-8 itself will not be transmitted.
■Channel voice messages
●Control Change
* The messages assigned in MIDI Setup will be transmitted when you operate
the panel. The control changes that can be used are CC#1–5, 7–31, and
64–95. For the factory settings, refer to "Settings Transmitted/Received
Using MIDI" (p. 96).
❍Bank Select (controller numbers 0, 32)
Status
2nd byte
BnH
00H
BnH
20H
mm,ll=bank number: 00 00H - 7F 7FH (bank.1 - bank.16384)
* Sent in combination with Program Change message when an input
selection is made.
* The following controls correspond to each Bank Select message.
--------------------------------------------------------------------------------------------------------
Bank Select
Program No.
MSB | LSB
--------------------------------------------------------------------------------------------------------
50H | 00H (bank.10241)
00H - 07H
--------------------------------------------------------------------------------------------------------
00H | 00H (bank.1)
00H - 07H
--------------------------------------------------------------------------------------------------------
01H | 00H (bank.129)
00H - 07H
--------------------------------------------------------------------------------------------------------
❍Modulation (controller numbers 1)
Status
2nd byte
BnH
01H
❍Breath-type (controller numbers 2)
Status
2nd byte
BnH
02H
❍Foot-type (controller numbers 4)
Status
2nd byte
BnH
04H
❍Portamento Time (controller numbers 5)
Status
2nd byte
BnH
05H
❍Volume (controller numbers 7)
Status
2nd byte
BnH
07H
❍Balance (controller numbers 8)
Status
2nd byte
BnH
08H
❍Panpot (controller numbers 10)
Status
2nd byte
BnH
0AH
❍Expression (controller numbers 11)
Status
2nd byte
BnH
0BH
❍Effect Control 1 (controller numbers 12)
Status
2nd byte
BnH
0CH
❍Effect Control 2 (controller numbers 13)
Status
2nd byte
BnH
0DH
❍General Purpose Controller 1–4 (controller numbers 16–19)
Status
2nd byte
BnH
10H - 13H
❍Hold 1 (controller numbers 64)
Status
2nd byte
BnH
40H
❍Portamento (controller numbers 65)
Status
2nd byte
BnH
41H
❍Sostenuto (controller numbers 66)
Status
2nd byte
BnH
42H
92
3rd byte
mmH
llH
Control
MEMORY 1 - 8
Bus A INPUT 1 - 8
Bus B INPUT 1 - 8
3rd byte
vvH
3rd byte
vvH
3rd byte
vvH
3rd byte
vvH
3rd byte
vvH
3rd byte
vvH
3rd byte
vvH
3rd byte
vvH
3rd byte
vvH
3rd byte
vvH
3rd byte
vvH
3rd byte
xxH
3rd byte
xxH
3rd byte
xxH
❍Soft (controller numbers 67)
Status
2nd byte
BnH
43H
❍Legato (controller numbers 68)
Status
2nd byte
BnH
44H
❍Hold 2 (controller numbers 69)
Status
2nd byte
BnH
45H
❍Sound Controllers1–10 (controller numbers 70–79)
Status
2nd byte
BnH
46 - 4FH
❍General Purpose Controllers 5–8 (controller numbers 80–83)
Status
2nd byte
BnH
50 - 53FH
❍Portamento Control (controller numbers 84)
Status
2nd byte
BnH
54H
❍Effect Depth 2–5 (controller numbers 92–95)
Status
2nd byte
BnH
5C - 5FH
●Program Change
Status
2nd byte
CnH
ppH
pp=program number: 00H - 7FH (prog.1 - prog.128)
* Sent in combination with Program Change message when an input
selection is made. For more detailed information refer to the Bank Select
parameters.
●Channel Pressure
Status
2nd byte
DnH
vvH
* Just as for Control Changes, the messages assigned in MIDI Setup will be
transmitted when you operate the panel. For the factory settings, refer to
"Settings Transmitted/Received Using MIDI" (p. 96).
●Pitch Bend Change
Status
2nd byte
EnH
llH
mm, ll = pitch bend value: 00 00H - 40 00H - 7F 7FH (-8192 - 0 - +8191)
* Just as for Control Changes, the messages assigned in MIDI Setup will be
transmitted when you operate the panel. For the factory settings, refer to
"Settings Transmitted/Received Using MIDI" (p. 96).
●Data Set 1 (DT1)
This is the message that transfers actual data, and is used to specify data for a
device.
Status
Data bytes
F0H
41H, dev, 00H, 00H, 28H, 12H,
aaH, bbH, ccH, ddH, ..., eeH, sum
Byte
Explanation
F0H
Exclusive status
41H
ID number (Roland)
dev
Device ID (dev: 00H - 1FH, factory setting is 10H)
00H
1st byte of model ID (V-8)
00H
2nd byte of model ID (V-8)
28H
3rd byte of model ID (V-8)
12H
Command ID (DT1)
aaH
Upper byte of address
bbH
Address
ccH
Address
ddH
Data: the actual data to be transmitted. Multi-byte data is
transmitted in the order of the address.
:
:
eeH
Data
sum
Checksum
F7H
EOX (End Of Exclusive)
* For details on setting the address, size, and checksum, refer to "Exclusive
message examples and checksum calculation" (p. 96).
* Data that exceeds 256 bytes must be divided into packets of 256 bytes or
less for transmission. If a subsequent "Data Set 1" message is transmitted,
an interval of at least 20 ms must be left between packets.
3rd byte
xxH
3rd byte
xxH
3rd byte
xxH
3rd byte
vvH
3rd byte
vvH
3rd byte
vvH
3rd byte
vvH
3rd byte
mmH
Status
F7H