Ethernet Port

* * * * * * * * * * M M A A I I N N M M E E N N U U * * * * * * * * * *
EVENTS SELEC.
ANALOG OUTPUTS
SERIAL OUTPUT
ETHERNET PORT
R R E E V V . . 1 1 . . 4 4 . . 2 2 . . 6 6
1
* * * * * * * * E E T T H H E E R R N N E E T T M M E E N N U U * * * * * * * *
IP ADDRESS
GATEWAY
MODBUS TCP/IP
2
192. 168. 2. 122
IP
2a
MASK
255. 255. 255. 0
123...
PORT ?
min
2c
max
123...
000. 000. 0. 000
GW IP
2b
123...

Digital filter

* * * * * * * * * * M M A A I I N N M M E E N N U U * * * * * * * * * *
EVENT SELEC.
ANALOG OUTPUTS
SERIAL OUTPUT
FILTER
R R E E V V . . 1 1 . . 4 4 . . 2 2 . . 6 6
1
* * * * * * * * * * M M A A I I N N M M E E N N U U * * * * * * * * * *
RANGE
COEFFICIENT
2
RANGE
min
3
max
Confirm
COEFFICIENT
min
max
4
Confirm
This function allows the user to set the Ethernet port. Choose the
ETHERNET PORT function
Measure
firm with "S".
IP ADDRESS (2): set the IP parameters. Select IP ADDRESS by
> 2s
means of the "
( ( A A V V 5 5 ) )
address) or MASK (netmask) by means of the "
firm with "S". Set the value
the "
lowing number. Confirm with "S".
Go back
GATEWAY (2): set the IP gateway parameters. Select GATEWAY by
means of the "
means of the "
> 2s
and the "
MODBUS TCP/IP (2): to modify the default port of the Ethernet port
(502), select MODBUS TCP/IP by means of the "
firm with "S". Set the value (2b), from 1 to 65535, by means of the
"
Go back
To exit the various menus and submenus, keep the "S" key pressed
> 2s
for at least 2 seconds.
50200.
100000
655350
Go back
> 2s
Thanks to the digital filter, it's possible to stabilize the measurements
Measure
which are too instable when displaying the relevant values.
By means of the "
> 2s
the function to be set from the various submenus with the "
( ( A A V V 5 5 ) )
and confirm with "S":
RANGE (3): set the operating range of the digital filter. The value is
expressed as a %. By means of the "
confirm with "S", then set the value as a percentage by means of the
Go back
"
COEFFICIENT (4): set the filtering coefficient of the instantaneous
measures. By increasing the value, also the stability and the settling
> 2s
time of the measures are increased. Select COEFFICIENT by means of
the "
means of the "
1,000%
0.100%
100.0%
123...
4,000%
1.100%
255.0%
123...
Programming WM5 96
" keys and confirm with "S". Then select IP (IP
" key increases the value and the "
" keys and confirm with "S". Set the value
" keys, where the "
" key switches to the following number. Confirm with "S".
" keys and confirm with "S".
" keys, select FILTER and confirm with "S". Select
" keys and confirm the value with the "S" key.
" keys and confirm with the "S" key, then set the value by
" keys and confirm the new value with the "S" key.
(1)
by means of the "
(2a)
by means of the "
" key switches to the fol-
" key increases the value
" keys select RANGE and
33
" keys and con-
" keys and con-
" keys, where
(2b)
by
" keys and con-
" keys