Programming Keypad; Resets; Access To Programming - CARLO GAVAZZI WM5-96 - PROGRAMMING Instruction Manual

Smart power quality analyzer
Table of Contents

Advertisement

WM5-96 Instruction Manual

Programming keypad

1

Resets

PASS ?

Access to programming

PASS ?
1
* * * * * * * * * * M M A A I I N N M M E E N N U U * * * * * * * * * *
a
CHANGE PASSWORD
MODULES
b
SYSTEM
CT RATIO
R R E E V V . . 1 1 . . 4 4 . . 2 2 . . 6 6
2
d
The "S"
modified data and go back to the previous data if pressed for at least
2 seconds. The "
modify the selected values/data. To modify the values proceed as fol-
lows: the "
from 0 to 9, to move to the next digit, use the "
case the system is cyclical.
2
3
Example, enter the value 213: starting situation 000, press "
to increase the number up to 2, then press "
digit (on the right); the instrument displays 200, press "
increase the number to 1, then press "
(on the right); the instrument displays 210, press "
increase the digit to 3, press "S" to confirm the value. If you do not
want to confirm the value, but only to modifiy it, press the "
By means of a single command and only from the "P00" page, you
can carry out the reset of all the min. and max. values, the dmd and
Measure
dmd max values, the reset of all the logged events and of the alarms
with latch. To carry out this reset command you have to enter some
numeric codes: press the "S" key, the instrument displays the "
0000
> 2s
indication. Enter by means of the "
codes depending on the reset you want to carry out.
5784= reset of all the minimum and maximum values;
5785= reset of all the "dmd" and "dmM" (dmd max) values;
7239= reset of all the "events";
9288= reset of the alarms with latch.
To access the programming menus from the measuring and display
phase, press the "S" key (only from the "P00" page), when the pass-
Measure
word "PASS?" is requested, enter the correct PASSWORD value by
means of the "
> 2s
0000
again. If the PASSWORD is correct (for all instruments the PASS value
when they leave the factory is "0"), the instrument will enter the main
menu.
To cancel the choice and go back to the measuring mode, press the
123...
"S" key for at least 2 seconds.
Measure
a
b
> 2s
c
c
( ( A A V V 5 5 ) )
d
e
e
Programming WM5 96
(1)
key is used to enter programming, confirm the selected or
" keys at N. 6 are used to scroll the menus and
"
(2)
key increases in a cyclical way the selected digit
" keys, then confirm by pressing the "S" key
Menu title.
Menu.
Scroll bar.
Firmware revision of the instrument.
Type of measuring analogue output being mounted on the instru-
ment.
11
"
(3)
key, also in this
" twice
" to go on to the next
" once to
" to go on to the next digit
" three times to
" key.
PASS?
" keys the following numeric
"