Programming WM5 96
28
Events selection
* * * * * * * * * * * * M M A A I I N N M M E E N N U U * * * * * * * * * * * *
DIGITAL INPUTS
DIGITAL OUTPUTS
ALARMS
EVENTS SELEC.
R R E E V V . . 1 1 . . 4 4 . . 2 2 . . 6 6
1
E E V V E E N N T T S S S S E E L L E E C C T T I I O O N N M M E E N N U U
ALARMS
MIN
MAX
DMD MAX
DIG. INPUTS
2
* * * * * * * * A A L L A A R R M M E E V V E E N N T T S S * * * * * * * *
ALARM 01 (OFF)
ALARM 02 (ON)
ALARM 03 (ON)
ALARM 04 (ON)
ALARM 05 (ON)
2a
V1
(OFF)
v2
(ON)
V3
(ON)
VL
(ON)
2b
V12
(ON)
REMOTE (OFF)
SYNC
(ON)
2c
TARIFF
(ON)
E E V V E E N N T T S S S S E E L L E E C C T T I I O O N N M M E E N N U U
MAX
DMD MAX
DIG. INPUTS
DIG. OUTPUTS
RESET
3
3a
REMOTE (OFF)
TOT. PAR.
TOTAL +
TOTAL -
PARTIAL +
PARTIAL -
3b
PARTIAL +
PARTIAL -
MIN - MAX
DMD MAX
LATCH
TOTALIZERS
This sub-menu allows the user to select which events are to be
stamped. Choose the function EVENTS SELEC.
"
Measure
ALARMS (2): select if the alarm events are to be stamped. Choose
alarms by means of the "
> 2s
alarm by alarm by means of the "
( ( A A V V 5 5 ) )
stamping is to be enabled "ON" or disabled "OFF", by pressing the
"S" key.
MIN, MAX, DMD MAX (2): select whether to store the minimum, max-
imum and dmd values for each variable measured by the instrument.
Measure
Select the minimum, maximum or dmd maximum by means of the "
" keys and confirm with "S", then select, variable by variable if the
> 2s
storing is to be carried out (2b), choose by means of the "
the desired variable and decide whether to enable the storing "ON" or
disable the storing "OFF" by pressing the "S" key.
DIG. INPUTS (2): select whether to store the status variables of the
digital inputs. Choose DIG. INPUTS by means of the "
confirm with "S", then select one by one the digital inputs of which the
Go back
storing is required (2c), choose by means of the "
of digital inputs (remote, synchronism, tariff), then confirm whether to
> 2s
enable the storing "ON" or disable it "OFF" by pressing the "S" key.
DIG. OUTPUTS (3): select whether to store the status variations of the
digital outputs or not. Select the digital outputs by means of the "
keys and confirm with "S", then confirm whether to enable the storing
"ON" or disable it "OFF" by pressing the "S" key.
RESET (3): select whether the resets which have been carried out are
Go back
to be stored or not. Choose RESET by means of the "
then select which resets are to be stored (3b), by means of the "
> 2s
keys and select whether to enable the storing "ON" or disable it "OFF"
by pressing the "S" key.
Go back
> 2s
Go back
> 2s
Go back
> 2s
(OFF)
(ON)
Go back
(ON)
(ON)
(ON)
> 2s
(OFF)
(ON)
(ON)
(ON)
(ON)
(ON)
" keys and confirm with "S". Afterwards proceed as follows:
WM5-96 Instruction Manual
(1)
by means of the
" keys and confirm with "S", then ,
" keys, decide whether the
" keys the type
" keys
" keys and
"
" keys,
"
Need help?