Poor Charging (Battery Over Discharging Or Overcharging); Undercharging; Overcharging - KYMCO AGILITY 125 Service Manual

Hide thumbs Also See for AGILITY 125:
Table of Contents

Advertisement

1
. GENERAL INFORMATION

POOR CHARGING (BATTERY OVER DISCHARGING OR OVERCHARGING)

Undercharging

Inspection/Adjustment
Start engine and test
limit voltage between
battery terminals
Measure resistance
between AC generator
coil terminals
Connect battery (+) wire
to regulator/rectifier
coupler red wire and
battery (-) wire to engine
ground and test voltage
Check regulator/rectifier
coupler for loose
connection

Overcharging

Inspection/Adjustment
Connect battery (+) wire
to regulator/rectifier
coupler green wire and
battery (-) wire to engine
ground and test voltage
Check regulator/rectifier
coupler for loose
connection
Symptom
Normal voltage
Normal
Normal voltage
Normal
Symptom
Battery has voltage
with ignition
switch "ON"
Normal
Voltage does not
increase
Resistance too high
No voltage
Abnormal
Battery has no
voltage with ignition
switch "ON"
Abnormal
AGILITY 50
Probable Cause
Dead battery
Faulty battery
Faulty A.C. generator coil
Broken yellow wire
Loose connector
Broken red wire
Faulty regulator/rectifier
Poorly connected coupler
Faulty A.C. generator
Probable Cause
Broken green wire
Poorly connected coupler
Faulty regulator/rectifier