KYMCO AGILITY 125 Service Manual page 155

Hide thumbs Also See for AGILITY 125:
Table of Contents

Advertisement

14
. BATTERY/CHARGING SYSTEM/
A.C. GENERATOR
SPECIFICATIONS
Battery
A.C. Generator
Regulator/Rectifier
Resistor
TORQUE VALUES
Pulser coil bolt
Stator bolt
Flywheel nut
Cooling fan bolt
SPECIAL TOOLS
Universal holder
Flywheel puller
TESTING INSTRUMENTS
Kowa electric tester
Sanwa electric tester
TROUBLESHOOTING
No power
Dead battery
Disconnected battery cable
Fuse burned out
Faulty ignition switch
Low power
Weak battery
Loose battery connection
Charging system failure
Faulty regulator/rectifier
Item
Capacity/Model
Voltage
Fully charged
(20 )
Undercharged
Charging current
Charging time
Capacity
Lighting coil resistance (20 )
Charging coil resistance (20 ) White Green
Type
Lighting
Limit voltage
Charging
Resistance (20 )
Resistance (20 )
12V 4AH
13.1V
12.3V
STD: 0.4A Quick: 4.0A
STD: 5 10hr Quick: 30min
0.144KW/5000rpm
Yellow Green
Single-phase half-wave SCR
13.1 13.9V/5000rpm (
13.1 0.5V
14.5 0.5V/5000rpm
5W12
30W7.5
0.45~0.6kgf-m
0.8~1.2kgf-m
3.5~4.5kgf-m
0.8~1.2kgf-m
Intermittent power
Loose battery cable connection
Loose charging system connection
Loose connection or short circuit in
lighting system
Charging system failure
Loose, broken or shorted wire or connector
Faulty regulator/rectifier
Faulty A.C. generator
AGILITY 50
Standard
0.1 1.0
0.2 1.2
Electric tester, tachometer)
14-2

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Agility 50Agility 50 4t r10Agility 50 4t r12

Table of Contents