Table 8-3. Warning Events (continued)
54
SCSI: failure in LME interface
55
SCSI: invalid license key entered
58
Recovered Error: SCSI parity error
59
Recovered Error: Error log overflow
5A
Illegal request, downgrade prohibited
5B
Incompatible medium generation
5C
Illegal request, downgrade prohibited
because of incompatible network stack
5D
Illegal request, wrong drive FW for drive Obtain correct drive firmware image.
5E
Full height drive in illegal position
60
Cleaning cartridge installed
61
Cleaning failure. Cleaning process could
not be performed
62
Cleaning cartridge expired
63
Invalid cartridge. Drive has rejected the
data cartridge as invalid
64
Invalid cleaning cartridge. Drive has
rejected the cleaning cartridge as invalid
65
Invalid upgrade cartridge. Drive has
rejected the upgrade cartridge as invalid
66
Medium error; diagnostic tape write
protected
67
Medium error, incompatible medium for
write operation
70
Currently not used
71
Currently not used
72
Currently not used
73
SCSI: overlapped command attempt
74
SCSI: echo buffer overwritten
DB
External cooling fan error (fan motion
has stopped).
The subcode indicates which drive sled
fan is affected
Subcode 01: drive sled #1(bottom)
Subcode 02: drive sled #2
8-12
Dell PowerVault TL2000 Tape Library and TL4000 Tape Library User's Guide
1. Check your Encryption configuration.
2. Run Key Path Diagnostics.
3. Refer to your EKM server documentation.
Re-enter license key. If problem persists, refer to technical
support.
No user action is required.
Disable encryption for firmware downgrade.
Replace incorrect cartridge(s).
Change network settings to IPv4 only before downgrading
firmware.
Check correct Drive position.
Complete the cleaning process and retry the operation.
1. Verify that autoclean is enabled.
2. Check for an expired cleaning cartridge and replace if
necessary.
3. Refer to "Configuring I/O Stations and Reserving Slots"
on page 5-65.
Replace cleaning cartridge.
1. Verify that the correct cartridge is being used. Refer to
"Cartridge Compatibility" on page 6-2.
2. Refer to "Identifying a Suspect Cartridge" on page 7-12.
Not supported
Ensure diagnostic tape is not write protected.
Replace incorrect cartridge(s).
Refer to your host application documentation for problem
determination information.
Refer to "Isolating Drive Sled Problems" on page 7-9.