Enrolling Keyfob Transmitters; Deleting Keyfob Transmitters; Enrolling Proximity Tags (Optional) - Visonic POWERMAXCOMPLETE User Manual

Fully supervised wireless alarm control system
Hide thumbs Also See for POWERMAXCOMPLETE:
Table of Contents

Advertisement

Enrolling Keyfob Transmitters

Keyfob transmitters are multi-button wireless units of
the CodeSecure™ type with up to 16 million ID
codes combinations. Eight system users carry keyfob
transmitters to exercise better, quicker and safer
system functions control. Your control panel must
recognize the unique identification code (ID) of each
such keyfob to respond to commands transmitted by
them.
Before anything else, gather up all keyfob units you
intend to enroll, and make sure they all have
batteries installed.
Keyfob transmitter enrolling involves the following
steps:
A. Having
entered
successfully (see above - Entering the User
Settings Menu), Click the
(repeatedly, if necessary) until the display will read:
ENROLL KEYFOB
B. Click
. The display will read:
KEYFOB No:
C. Suppose that the Keyfob you are about to enroll
is to be designated as Keyfob No. 5. Assuming
that memory location No. 5 is free - no keyfob has
yet been enrolled to it - click the <5> key. The
display will change to:
KEYFOB No:
The clear space at the far right tells you that the
memory location is free.
D. Click
. The display will prompt you to
initiate a transmission from the chosen keyfob:
TRANSMIT NOW
E. Initiate a transmission from the chosen keyfob by
pressing any one of its pushbuttons. In response,
the "Happy Tune" (- - - –––) will sound. When
partition is disabled, the display will read:
KEYFOB No: 5
Proceed to step "I" below.
When partition is enabled, the display will read:
ACCESS TO PART
F. Click
F01: P1
G. Select the desired partitions via pushbuttons 1, 2
and 3 on the control panel keypad.
H. Click
. The display will read:
KEYFOB No:
A dark box will appear at the far right, indicating
that the chosen Keyfob has been enrolled as
Keyfob No. 5.
I.
From this point on, you may continue in several
different directions:
If you wish to enroll another keyfob, select
the desired number by:
D-302755
your
Master
User
_
5
. The display will read
P2
P3
5
- Clicking
- Clicking
- Clicking
To return to the main menu, click
will bring back the display:
You may now review and select any other mode on
the User menu (by clicking

Deleting Keyfob Transmitters

Occupied keyfob memory locations must be cleared
(enrolled ID must be deleted) before enrolling a new
Code
ID. To delete an existing ID, proceed as follows:
button
A. Select the desired memory location, as described
in the previous paragraph, steps A-C. If, for
example, you selected keyfob No. 5, the display
will read:
B. Click
C. Click
Note that the dark box at the far right has
disappeared. It is now possible to enroll a new ID. It
is also possible to leave the cleared keyfob location
free and simply exit to the main menu.

Enrolling Proximity Tags (optional)

When partition is enabled: Each proximity tag
assigned to a partition will function as determined in
"Setting the User Codes". Therefore, each proximity
tag must be assigned a relevant user code. For
example, proximity tag 3 is assigned to user code 3.
Up to 8 proximity tags can be enrolled to the
PowerMaxComplete control panel.
Proximity tag enrolling involves the following steps:
A. Having
successfully (see Entering the User Settings
Menu),
(repeatedly, if necessary) until the display will
read:
B. Click
C. Click
to initiate a transmission from the chosen tag:
USER SETTINGS
to go up (6 7 8.....)
to go down (4 3 2.....)
<keyfob #>.
<OK> TO EXIT
Keyfob No.
. The display will change to:
<OFF> to delete
. The display will change to:
Keyfob No.
entered
your
Master
Click
the
E N R O L L
P R O X T A G
. The display will read:
T a g N o :
1
. The display will prompt you
P R E S E N T T A G
. This
or
).
5
5
User
Code
button
29

Hide quick links:

Advertisement

Table of Contents
loading