Troubleshooting
Free Bound Virtualized Storage when the Master System Fails
STEP 1
STEP 2
Free Bound Virtualized Storage when the Master System Fails
STEP 1
STEP 2
STEP 3
STEP 4
STEP 1
STEP 2
Linksys Small Business NSS4000 and NSS6000 Series Network Storage System Administration Guide
•
If you are upgrading within a virtualized setup, make sure that you installed
the firmware in the order described in
page
129.
To update the firmware after a failed attempt:
Click OK when the message appears from the System Details page that the
firmware upgrade was not successful.
The system automatically reboots using the current firmware version. The
Power LED blinks green and then goes solid green when the reboot
completes.
Go through the steps to upgrade the firmware.
A storage system is bound to a failed storage system and rejects any bind
requests from other systems.
Follow these steps to recreate the problem:
Export storage from System A.
Import storage from System A to System B.
System B crashes and cannot be recovered.
System A is "bound" to System B and rejects any new bind requests from other
systems.
To resolve the problem:
Unexport the bound storage system (in our example, System A).
Re-export the storage system.
The storage system is now available to be used by another system.
"Upgrading the NSS Firmware" on
A
162