Troubleshooting

Repairing a Degraded Array

Repairing a Degraded Array
Linksys Small Business NSS4000 and NSS6000 Series Network Storage System Administration Guide
Off: The drive is OK.
The white LED means that that there is a locate request currently on the disk drive:
Blinking White: There is a locate request currently on the disk drive (see
"Storage Status," on page 6
only be one locate request set for a disk drive at one time.
Off: The disk drive is not marked by a locate request.

USB LED (Front Panel)

Solid Green: The USB hard/flash drive is connected and is not safe to
remove.
Blinking Green: The USB hard/flash drive is connected and is being
mounted or unmounted.
Off: There is either no USB hard/flash drive connected to the NSS, or, if
connected, the USB hard/flash drive is safe to remove.

UPS LED (Back Panel)

Off: There is either no UPS attached to the NSS or the UPS function has
been disabled in the System Power page in the configuration interface.
On: A UPS is attached to the NSS and the UPS function is enabled in the
System Power page in the configuration interface.
For more information about the UPS, refer to the UPS documentation.
If a RAID level 1, 5, or 10 is in a degraded state (that is, a redundant disk drive has
failed), you can replace the failed disk drive(s). (You might be able to use some of
the data on a JBOD if there are volumes that do not span across the failed disk.
Otherwise, you must rebuild the JBOD after you replace the disk.) If an array with
no redundancy has a failed disk drive, you must delete the array, replace the disk
drive, and then recreate the array.