Unit Parts

Unit Parts - Part 1
Unit Parts - Part 2
Unit Parts - Part 3

Tools Required

Tools Required

Remember to take care when unpacking. Please keep your workspace clean, clear and tidy when working. This will help keep all items safe from any damage. Any waste cardboard or plastic should be flattened down and placed in the bin.

A minimum of two people will be needed to lift the unit.

Removing the frontals

Removing the frontals
Before installing the unit, remove each frontal by pulling the release catch.
Place the frontals in the door safe along their longest length.

Removing the drawer

Removing the drawer
Before installing the unit, remove the drawer. This is done by pulling the drawer all the way out, and then pulling the front of the drawer upwards.

Place the drawer on top of a piece of leftover cardboard to protect it from damage.

Removing the fixtures and fittings

Removing the fixtures and fittings
Remove all fixtures and fittings from the unit and keep on a clean and level surface, grouped by product. Place any loose shelves in the door safe along their longest length.

Positioning the leg brackets

Locate the leg brackets and position, as shown in the diagram. Ensure the leg brackets are rotated so the flange covers the outer edge, as this provides support for the edge of the unit.
Positioning the leg brackets - Step 1
Positioning the leg brackets - Step 2

Fixing the leg bases


Secure each of the leg brackets into place with 4x15mm screws per bracket.

Inserting the legs

Inserting the legs
Push each leg firmly down into the leg bracket. Adjusting each leg to 165mm.
Adjust the legs to the correct height by turning clockwise or anti-clockwise.

Notching out the side panels

Notching out the side panels
(when required)
In order to allow for any horizontal pipework running behind the unit, some units will require the back of the unit sides to be notched out.
Create a notch for the horizontal pipes at the back of the end panels using a jigsaw.

Lifting the unit into place

Lifting the unit into place
When lifting the unit into place do not tilt as this can damage the legs.
Place the unit against the wall and align it with the wall markings that will have been drawn during the room preparation stage.
Use a spirit level to ensure the unit is level from front to back, left to right, and diagonally. Adjust the legs if required.
The leg height can be adjusted by turning the foot of the leg clockwise or anti-clockwise.

No screws or wall plugs are provided for attaching the unit to the wall.
This is due to variations in wall construction.

Before drilling into the wall you MUST check for any hidden services or pipework within the walls.

Drilling the pilot holes

Drilling the pilot holes
Drill 2 pilot holes through the back panel making sure to lightly mark the wall to indicate where the wall fixings should be placed. The holes should be located as per the diagram, 1/3 in from each side and close to the top of the unit.
For guidance on the appropriate wall fixing for each wall type, please consult the "Room Preparation Guide."
Once complete lift and move the unit away from the wall.
Using each pilot hole, drill a hole to suit the fixing. Place the wall fixing within the hole.
Lift and reposition the unit, ensuring it is level and in line with the wall markings.

Inserting the space plugs

Inserting the space plugs
Position the space plugs between the wall and the back of the unit, where the holes are located.
Unwind until the space plugs touch both the back panel of the unit and the wall.
Insert the screws into the drilled holes and tighten to the wall.

Securing to adjacent units

Securing to adjacent units
Clamp together the two units, checking the front edges are level and flush.
Using the screws provided, 1x30mm screw should be fixed into each corner of the unit side.
The screws can be concealed by placing them behind the shelf or behind the hinge plates. The cover caps can be used to hide any visible screw heads that remain.

Finding the shelf height

 Finding the shelf height
Position the shelf pegs into the pre-drilled holes. The shelf can be positioned at 3 different heights, as shown in the diagram.

Placing the shelf into position

Placing the shelf into position
Place the shelf into position so the pin of each shelf peg is inserted into the pre-drilled holes.
The shelf will touch the back panel when installed, if there is a gap between the back panel and shelf then it has been installed back to front and needs to be rotated.

Inserting the drawer

Inserting the drawer
Slide the drawer onto the runners, make sure the runner mechanism and the drawer sides' groove line up.
Push the drawer back into the unit. After it has been positioned on the runners; you should hear a click.

Adjusting the drawer frontal horizontally

Adjusting the drawer frontal horizontally
Use the fixing clips, which are found under the drawer's front, to adjust the drawers.

  1. Press the fixing clips half way to meet the runners on the underside of the drawer.
  2. Slide the drawer to the left or right to adjust.
  3. Release the fastening clips on both sides of the drawer to lock the frontal in place.

Adjusting the drawer frontal height

 Adjusting the drawer frontal height
To adjust the height of the frontal, use a screwdriver to loosen the screws on both sides of the inside of the drawer box.
Adjust the frontal height, then re tighten the screws to lock.
Push the supplied cover caps onto the adjustment screw heads.

Attaching the frontal

Attaching the frontal
The frontal should be re-attached to the unit by clipping the hinges onto the hinge plates. The bar of the hinge needs to be positioned into the hooks on the hinge plate. Then the rear of the hinge pushed to the hinge plate until it clicks.

Adding the door buffers

Adding the door buffers
Position 1x door buffer at the top and bottom corners of the unit, as illustrated in the image.

For door alignment please review the following installation guide:
Door - Door Frontal Hinge Adjustment

Cleaning the unit

Cleaning the unit
Finally, the unit should be thoroughly cleaned to remove any debris that may have accumulated during the installation.

Store the plinth clips and the remaining 15mm screws.
These will be used later when attaching the plinth.

Documents / Resources

Download manual

Here you can download full pdf version of manual, it may contain additional safety instructions, warranty information, FCC rules, etc.

Download Wren Kitchens INFINITY, INFINITY PLUS Manual

Advertisement

Need help?

Need help?

Do you have a question about the INFINITY and is the answer not in the manual?

Questions and answers

Table of Contents